Amcor AHW 164 user manual Rating Labels, Indoor Unit

Page 14

RATING LABELS

 

 

 

 

 

 

 

INDOOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

AHW 164

 

 

See barcode

 

230 V 60 Hz 1 Ph

 

 

 

 

 

 

 

Model

 

 

Serial number

 

Power supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.1 kW

 

 

 

13 BTU/h W

 

IP 20

 

 

 

 

 

18000 BTU/h

 

 

 

 

Cooling capacity

 

SEER

Protection class

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64-86 oF

 

1040 m3/h

 

R410A

 

 

 

18-30 oC

 

36700 cu.ft/h

 

Refrigerant

 

 

Thermostatic range

 

 

Airflow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

up to 40 L/day

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~44 - 50 dB(A)

 

18 kg / 40 lb

84 pts/day

 

 

 

Dehumification

 

 

 

Noise level

 

Weight net

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Caution:

1.Do not cover the air discharge openings.

2.Avoid risk of electric shock: disconnect before servicing.

3.Use only on a single outlet.

4.Wait 3 minutes after power has been switched off before restarting.

5.Moving parts inside:

do not operate when the cover is removed.

6.A damaged power supply cord must be replaced with a new one obtained from the manufacturer and may not be repaired.

VERIFIED

Energy Performance Rendement Énergetique SEER 13

 

VÉRIFIÉ

 

 

 

233041

SA 12793

 

 

 

 

 

www.amcorgroup.com

Made in P.R.C.

cat# 913136150

Carlstadt, New Yersey 07072

 

OUTDOOR

 

 

UNIT

 

AHW 164

See barcode

230 V 60 Hz 1 Ph

Model

Serial number

Power supply

1.2 kW

9.4 A

6.4 A

15 A

Minimum

 

Maximum

Rated power circuit amperage

Rated current current protection

5.1 kW

2.4 / 4 MPa

13 BTU/h W

18000 BTU/h

348/580 PSIG

Cooling capacity

Pressure range

SEER

Suction/Discharge

 

4.85 lb

50-104 oF

R410A

2200 g

10-40 oC

Refrigerant

Refrigerant load

Operating range

IP 24

~65 dB(A)

62 kg / 137 lb

Protection class

Noise level

Weight net

Caution:

1.Do not cover the air discharge openings.

2.Avoid risk of electric shock: disconnect before servicing.

3.Use only on a single outlet.

4.Wait 3 minutes after power cut before restarting.

5.Moving parts inside:

do not operate when the cover is removed.

6.A damaged power supply cord must be replaced with a new one obtained from the manufacturer and may not be repaired.

7.Specification of the connecting wires: 14 AWG, VW-1 (or THHW), copper core and 90 °C.

VERIFIED

Energy Performance Rendement Énergetique SEER 13

VÉRIFIÉ

233041

SA 12793

www.amcorgroup.com

Made in P.R.C.

cat# 913136160

Carlstadt, New Yersey 07072

Data provided is subject to modifications and is not legally binding.

14

Image 14
Contents High Wall Split AIR Conditioner Safety Instructions Thank YOUDo not use your air conditioner when Dehumidifying HOW IT WorksCooling LCD display Remote ControlUsing the remote control Replacing the batteriesOperation Setting the timeAuto mode GeneralTimer on function Fan modeSleep mode Timer off functionAuto restart Air flow direction Fins vertical vanesVanes Range of internal thermostatEmergency start Turn the appliance off and disconnect the powerFilters Start of Period of USE CleaningEND of Period of USE Exterior unitInstallation Guidelines Connection of the Wires of the Outdoor Unit Trouble Shooting Rating Labels Indoor UnitPage Israel