Amcor AHW 164 user manual HOW IT Works, Cooling, Dehumidifying

Page 4

HOW IT WORKS

The compressor (6) in the exterior unit compresses the refrigerant into a high-temperature, high-pressure gas. When this gas flows along the cooling fins of the condenser (7), heat is exuded and the gas condenses into a liquid, which is led to the evaporator (1) in the interior unit. The liquid expands into a

gas at a low temperature and low pressure.

This gas absorbs the warmth of the air in the room, the cooled air is blown back into the room and the heat is led to the compressor along with the gas.

1

a

2

3

b

4

c

6 7 5

d

8

1. Evaporator

5. Liquid line

2. Filter

6. Compressor

3. Fan

7. Condenser

4. Gas line

8. Fan

Cooling

A fan (3) draws the air (a) over the filter (2) and blows the cooled air (b) back into the room.

A fan (8) draws air over the condenser and blows warm air (d) away.

Dehumidifying

As with cooling, the moisture in the air condenses on the cold evaporator at room temperature.

4

Image 4
Contents High Wall Split AIR Conditioner Safety Instructions Thank YOUDo not use your air conditioner when Cooling HOW IT WorksDehumidifying Remote Control Using the remote controlLCD display Replacing the batteriesSetting the time Auto modeOperation GeneralFan mode Sleep modeTimer on function Timer off functionAir flow direction Fins vertical vanes VanesAuto restart Range of internal thermostatFilters Turn the appliance off and disconnect the powerEmergency start Cleaning END of Period of USEStart of Period of USE Exterior unitInstallation Guidelines Connection of the Wires of the Outdoor Unit Trouble Shooting Rating Labels Indoor UnitPage Israel