Harman Stove Company TL2.0 manual Disposal of Ashes

Page 26

TL2.0 Woodburning Stove

Providing you have the charcoal bed described, close the bypass damper by pulling the handle toward the front of the stove. This will begin the highly efficient mode of operation where the exhaust gases get re- burned in the secondary combustion package. If you cannot achieve a charcoal bed within the first 15 to 20 minutes, your wood is likely too wet, and you may need to burn the fire longer and/or hotter to compensate for the extra energy needed to drive out the moisture. If, after five minutes of burning with the damper closed, smoke is visible coming from the chimney, you probably do not have the proper coal bed. Open the bypass damper and continue with the process until a significant coal bed is formed.

Always remember to open the bypass damper when you are loading, this allows the exhaust gases to pass directly into the flue outlet and reduces the chance of smoke spillage into the room.

Reloading: Once you have prepared and maintained a thick charcoal bed, and the secondary combustion is established, you should be able to reload the stove at any time by simply opening the bypass damper, then the load door, adding fuel and closing the door then the damper. This depends on coal bed size, load size and moisture content of fuel.

Removing Ashes: Before reloading, empty the ash pan (remember to close the ash door while emptying the pan). The ashes should be the coolest at this time. Remove ashes from the fire chamber periodically by raking a poker across the bottom grates.

Excessive ash buildup can prevent proper venting of exhaust gases. Do not allow the ash pan to over-fill. Ash buildup between the ash pan and the bottom of the grate can cause the grate to overheat and wear out prematurely.

The TL2.0 is designed to provide access to the ash pan without the need for opening the main door. Before opening the ash door and removing the ash

pan, open the bypass

damper. Wearing

heavy protective

gloves, open the ash

door and remove the

ash pan by pulling

it forward by the

handle. Close the

ash door and damper

bypass before taking

the ashes outside for safe disposal.

DISPOSAL OF ASHES;

Ashes should be placed in a steel container with a tight fitting lid. The container of ashes should be moved outdoors immediately, and placed on a noncombustible floor or the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or oth- erwise locally dispersed, they should be retained in the closed container until all cinders have com- pletely cooled. Other waste shall not be placed in this container.

CAUTION

hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.

Never leave the stove unattended if either the ash or load door is open. Overfiring may result.

Risk of Excessive Temperatures. Keep Ash Door Closed During Firing of the Heater.

Avoid overfiring your stove. Overfiring is a potentially hazardous situation which can lead to overheating of combustible materials nearby, damage to the stove, and in extreme cases, cause a fire. Overfiring is caused by:

1.Too much air flowing through the stove too quickly. 2. You may have positioned the primary air control lever too far to the right. 3. Inadvertently leaving the damper open or 4. Not keeping up with routine maintenance, such as checking door gaskets for wear.

Overfiring results in excessive fuel consumption, and may cause parts of the stove or chimney connector to glow red. If you notice signs of overfiring, reduce the air supply to the fire, and review the Maintenance section in this manual.

In the event of a chimney fire, call your local fire department; make sure everyone is safely out of the house. Reduce the air intake of the stove as much as possible using the air control lever; close the bypass damper to further restrict air flow. Do not throw water on the fire; this can cause stove damage and create an even more dangerous situation. Have your chimney professionally cleaned and inspected before resuming burning in your stove.

As you begin to operate your stove at higher temperatures, you will notice a “hot” or unpleasant smell; this is just the paint going through the curing process, and will disappear after a few fires.

26 Dry Seasoned Wood Only!

3-90-08560

Save These Instructions

Image 26
Contents Installation and Operation Do Not DiscardHouse Fire May Result. To Reduce The Risk Fire, Follow The Installation Instructions. ContactInstallation Inspection Requirements In Your Hearth & Home Technologies, IncTable of Contents Mobile Home Approved This appliance is also approved for installation Shop1Listing and Code Approvals If the alarm sounds 2Special Warnings and Notes3Getting Started Design, Installation & Location ConsiderationsFire Safety Appliance LocationComponent Locations Pre- Use Check List Fire Risk4Dimensions & Clearances Appliance DimensionsVertical Venting Configuration Clearances To CombustiblesVertical Venting Configuration Horizontal Exit Floor Protection Floor Protection RequirementsFloor Protection Requirements RequirementsDraft Chimney ConnectorsChimneys and Venting Wall Pass-thrusChimney AN Approved U.S Wall PASS-THROUGHVenting to a Masonry Chimney Installing to a Prefabricated ChimneyExisting Masonry Chimneys Venting to a Masonry Fireplace ChimneyStandard Ceiling Installation with Factory Built Chimney Cathedral Ceiling Installation with Factory Built Chimney Airtight Insulated Clean-out Chimney Breach Fireplace Conversion with Combustible Wall Mobile Home Installation 6Mobile HomeLeveling the Appliance 7Appliance Set-UpOutside Air Attachment Optional Cooking GrillBrushed Stainless Trim Kit Option Optional Blower InstallationTop Air Grill Option Use only Blower 1-00-856002 With This ApplianceOperating Instructions Fuel Specifications General Operating InformationAlways wear fire retardant gloves When operating the stove Burning as a Fireplace GratesUser Controls Before Your First FireDisposal of Ashes Creosote- Formation and Need For Removal Service & MaintenanceSeasonal cleaning By User Wear Leather Gloves To Prevent Skin Burns General Maintenance ProceduresAsh Removal By UserFirebox Blower- If installedDisconnect Power Cord Before Servicing ChimneyReference Materials Service Parts Black W/Pedestal Part number list on followingStocked at depot Hardware Packages 50% 60% 70% 80% 90% 100% Grams Per HourAsK dealer for HelP Use this to choose the right size appliance for your needsLimited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService & Maintenance Log Page Page Signature of Boxer Proudly Printed On 100% Recycled Paper

TL2.0 specifications

The Harman Stove Company TL2.0 represents an evolution in heating technology, combining efficiency, design, and functionality for homeowners seeking reliable home heating solutions. This innovative stove is designed for those who prioritize both comfort and aesthetics, providing an excellent balance of performance and visual appeal.

One of the standout features of the Harman TL2.0 is its impressive heating capacity. With a heat output that can efficiently warm spaces up to 2,200 square feet, it is perfect for medium to large areas. This capability is paired with a sleek design that allows the stove to seamlessly integrate into various home interiors, making it a stylish addition as much as a functional one.

Incorporating advanced combustion technology, the TL2.0 is engineered to maximize efficiency while minimizing emissions. The stove utilizes a patented "intelligent control board" that enhances burn efficiency by optimizing air-to-fuel ratios in real-time. This not only helps in achieving a cleaner burn but also lowers fuel consumption, making it an eco-friendly choice for consumers.

The TL2.0 is constructed with high-quality materials, ensuring durability and longevity. The robust steel construction not only contributes to its sturdiness but also allows for efficient heat retention and distribution. Additionally, the ceramic glass door provides an elegant view of the flames, creating a warm ambiance in any room.

Another notable characteristic is Harman's commitment to user-friendly operation. The TL2.0 features a straightforward control panel that makes it easy for users to adjust settings and monitor performance. With programmable thermostats and remote control options, homeowners can manage their heating preferences effortlessly.

Safety is also a top priority for Harman, and the TL2.0 includes several built-in safety features such as an automatic shut-off system and a cool-to-the-touch exterior. These features provide peace of mind, especially in homes with children or pets.

Overall, the Harman Stove Company TL2.0 combines advanced technology, sleek design, and safety features that make it a top choice for anyone in the market for a reliable heating solution. It stands out as a model that not only meets but exceeds modern expectations for home heating. Whether for practicality or aesthetics, the TL2.0 is poised to keep homes warm and inviting for years to come.