1. Appliance Location

Consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation. When installing on a combustible floor, proper floor protection material must be used. See page 12 for details.

Maintain specified vent clearance to combustible requirements listed by the vent manufacturers instructions and all clearance to combustibles listed in this manual.

Check with your local building code agency before you begin your installation. Be sure local codes do not supersede UL specifications and always obtain the required permit so that insurance protection benefits cannot be unexpectedly cancelled. If any assistance is required during installation, please contact your dealer.

We recommend that a qualified building inspector and your insurance company representative review your plans before and after the installation.

Be sure to provide a source of fresh air to the room or directly to the appliance. Make-up air is needed to replace what the chimney draws away through the appliance.

Consider attaching outside air to the appliance. Certain conditions can create negative pressure within the dwelling. When this occurs, you may have trouble operating the wood stove. Worse yet, it may be strong enough to allow smoke leakage from the appliance. Installation on lower levels and in basements can be especially affected.

CAUTION

Do NOT connect this unit to a chimney flue servicing another appliance.

Do NOT connect to any forced air distribution duct or system.

B. Fire Safety

Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must maintain the designated air space around the chim- ney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.

To provide reasonable fire safety, the following should be given serious consideration:

1.Install at least one smoke detector on each floor of your home. Detectors should be located away from the heating appliance and close to sleeping areas. Follow the smoke detector manufacturer's placement and installation instructions, and be sure to maintain regularly.

2.A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers.

3.A practiced evacuation plan, consisting of at least two escape routes.

4.A plan to deal with a chimney fire as follows: In the event of a chimney fire:

a.Evacuate the house immediately.

b.Notify Fire Department.

c.Never apply water to a suspected chimney fire. Serious damage could occur.

WARNING

Fire Hazard

Do not operate appliance before reading and understanding the operating instructions.

Failure to operate properly may cause a house fire.

6 Dry Seasoned Wood Only!

3-90-08560

Save These Instructions

Image 6
Contents Installation and Operation Do Not DiscardHouse Fire May Result. To Reduce The Risk Fire, Follow The Installation Instructions. ContactInstallation Inspection Requirements In Your Hearth & Home Technologies, IncTable of Contents This appliance is also approved for installation Shop 1Listing and Code ApprovalsMobile Home Approved If the alarm sounds 2Special Warnings and Notes3Getting Started Design, Installation & Location ConsiderationsFire Safety Appliance LocationComponent Locations Pre- Use Check List Fire Risk4Dimensions & Clearances Appliance DimensionsVertical Venting Configuration Clearances To CombustiblesVertical Venting Configuration Horizontal Exit Floor Protection Floor Protection RequirementsFloor Protection Requirements RequirementsDraft Chimney ConnectorsChimneys and Venting Wall Pass-thrusChimney AN Approved U.S Wall PASS-THROUGHVenting to a Masonry Chimney Installing to a Prefabricated ChimneyExisting Masonry Chimneys Venting to a Masonry Fireplace ChimneyStandard Ceiling Installation with Factory Built Chimney Cathedral Ceiling Installation with Factory Built Chimney Airtight Insulated Clean-out Chimney Breach Fireplace Conversion with Combustible Wall Mobile Home Installation 6Mobile HomeLeveling the Appliance 7Appliance Set-UpOutside Air Attachment Optional Cooking GrillBrushed Stainless Trim Kit Option Optional Blower InstallationTop Air Grill Option Use only Blower 1-00-856002 With This ApplianceFuel Specifications General Operating Information Always wear fire retardant gloves When operating the stoveOperating Instructions Burning as a Fireplace GratesUser Controls Before Your First FireDisposal of Ashes Service & Maintenance Seasonal cleaningCreosote- Formation and Need For Removal By User Wear Leather Gloves To Prevent Skin Burns General Maintenance ProceduresAsh Removal By UserFirebox Blower- If installedDisconnect Power Cord Before Servicing ChimneyReference Materials Service Parts Black W/Pedestal Part number list on followingStocked at depot Hardware Packages 50% 60% 70% 80% 90% 100% Grams Per HourAsK dealer for HelP Use this to choose the right size appliance for your needsLimited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService & Maintenance Log Page Page Signature of Boxer Proudly Printed On 100% Recycled Paper

TL2.0 specifications

The Harman Stove Company TL2.0 represents an evolution in heating technology, combining efficiency, design, and functionality for homeowners seeking reliable home heating solutions. This innovative stove is designed for those who prioritize both comfort and aesthetics, providing an excellent balance of performance and visual appeal.

One of the standout features of the Harman TL2.0 is its impressive heating capacity. With a heat output that can efficiently warm spaces up to 2,200 square feet, it is perfect for medium to large areas. This capability is paired with a sleek design that allows the stove to seamlessly integrate into various home interiors, making it a stylish addition as much as a functional one.

Incorporating advanced combustion technology, the TL2.0 is engineered to maximize efficiency while minimizing emissions. The stove utilizes a patented "intelligent control board" that enhances burn efficiency by optimizing air-to-fuel ratios in real-time. This not only helps in achieving a cleaner burn but also lowers fuel consumption, making it an eco-friendly choice for consumers.

The TL2.0 is constructed with high-quality materials, ensuring durability and longevity. The robust steel construction not only contributes to its sturdiness but also allows for efficient heat retention and distribution. Additionally, the ceramic glass door provides an elegant view of the flames, creating a warm ambiance in any room.

Another notable characteristic is Harman's commitment to user-friendly operation. The TL2.0 features a straightforward control panel that makes it easy for users to adjust settings and monitor performance. With programmable thermostats and remote control options, homeowners can manage their heating preferences effortlessly.

Safety is also a top priority for Harman, and the TL2.0 includes several built-in safety features such as an automatic shut-off system and a cool-to-the-touch exterior. These features provide peace of mind, especially in homes with children or pets.

Overall, the Harman Stove Company TL2.0 combines advanced technology, sleek design, and safety features that make it a top choice for anyone in the market for a reliable heating solution. It stands out as a model that not only meets but exceeds modern expectations for home heating. Whether for practicality or aesthetics, the TL2.0 is poised to keep homes warm and inviting for years to come.