Empire Products RH-50-6 installation instructions Optional Blower Installation Instructions

Page 16

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

FRB-3 For Vented Room Heaters

Models

 

RH-50-(1, 2, 3, 4, 5, 6)

RH-50C-1

RH-65-(1, 2, 3, 4, 5, 6)

RH-65C-1

Figure 1

Installing Optional Blower

1.Remove rear shield (2 screws) and bottom reflector (4 screws). (See Figure 1)

2.Align blower cushion with bottom assembly air discharge opening. Foil face side of blower cushion should be placed upward.

3.Align blower housing with blower cushion and use two #10 x 1/2” (13mm) hex-head screws to attach blower housing to bottom assembly. (See Figure 2)

4.Save bottom reflector and rear shield (removed in Step 1) in the even the blower housing is removed from room heater.

Attention! Bottom reflector and rear shield must be at- tached to bottom assembly whenever the blower housing in removed from the room heater and the room heater is in operation.

5.Remove switch box cover from the switch box by removing the #8 x 1/4” (6mm) hex-head screw.

6.There are two screw holes on the lower back of the combus- tion chamber. Use only the left screw hole for mounting.

7.With the switch box perpendicular to the combustion chamber, align the round clearance hole on the switch box with the left screw hole on the combustion chamber (See Figure 3).

8.Attach switch box to the combustion chamber using the #10 x 1/2” (13mm) hex-head screw provided.

9.Attach switch box cover to the switch box by using the #8 x 1/4” (6mm) hex-head screw. (See Figure 4)

Figure 2

Figure 3

Figure 4

12822-3-0406

Page 16

Image 16
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications IntroductionInstalling a New Main Gas Cock GAS SupplyRecommended Gas Pipe Diameter Checking Manifold PressureVenting ClearancesLiner and Insulated Liner Vent Safety Shutoff System Thermostat OperationLighting Instructions fireTechnician. Force or attempted repair may result in a fire Or explosionPilot Flame Characteristics Main Burner Flame CharacteristicsPrimary Air Adjustment see On Propane gas, if a whistling noise resonation occursMaintenance TroubleshootingHOW to Order Repair Parts Parts List RH-50 & RH-65Parts View RH-50 & RH-65 Parts List RH-50C & RH-65C Index Part Description NumberParts View RH-50C & RH-65C Optional Blower Installation Instructions Wiring Wiring DiagramFan Control OilingService Notes Service Notes Service Notes

RH-50-6 specifications

The Empire Products RH-50-6 is a cutting-edge heating solution designed to provide efficient warmth and comfort in residential and commercial settings. Known for its robust construction and high-performance features, the RH-50-6 has become a popular choice among consumers looking for reliability and efficiency in heating.

One of the standout characteristics of the Empire RH-50-6 is its impressive heating capacity. With a powerful output designed to warm larger areas, this unit is ideal for spaces such as living rooms, basements, or even commercial environments. The RH-50-6 utilizes an advanced heating technology known as radiant heat, which warms objects and surfaces in the room directly, providing a consistent and comfortable temperature throughout the space.

Another key feature of the RH-50-6 is its sleek design. The modern aesthetics are complemented by a user-friendly interface, making it easy for homeowners to control their heating experience. The unit comes equipped with a digital thermostat that enables precise temperature regulation, allowing users to set their desired level of comfort with ease. Additionally, the thermostat can be programmed to maintain specific temperatures at different times of the day, optimizing energy usage and enhancing convenience.

The Empire RH-50-6 also prioritizes safety, equipped with several built-in safety features, including an automatic shut-off mechanism that activates if the unit overheats. This ensures peace of mind for users, particularly in family environments. The unit is designed to operate quietly, contributing to a serene atmosphere while maintaining warmth without disruptive noise levels.

Moreover, the Empire Products RH-50-6 emphasizes energy efficiency. The innovative design minimizes energy consumption while maximizing output, aligning with modern environmental standards and helping users reduce their utility bills. This eco-friendly characteristic makes it an attractive choice for those who are conscious of their environmental impact.

In summary, the Empire Products RH-50-6 stands out for its combination of powerful performance, user-friendly technology, and safety features. Whether for a large home or a commercial space, its ability to provide efficient and consistent heating is a testament to Empire’s commitment to quality and innovation. The RH-50-6 is not just a heating solution; it represents a blend of style, efficiency, and comfort that consumers can trust.