Fujitsu ASU12C1, ASU9C1, AOU9C1, AOU12C1 manual Timer Operation

Page 11

TIMER OPERATION

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See Page 6).

To Use the ON timer or OFF timer

1

Press the START/STOP button (Fig. 6 ¡).

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2

Press the TIMER button (Fig. 6 _) to select the OFF timer

or ON timer operation.

Each time the button is pressed the timer function changes in the following order:

To Cancel the Timer

Use the TIMER button to select “TIMER

RESET.”

The air conditioner will return to normal

operation.

To Change the Timer Setting

Perform steps 2 and 3.

 

 

 

 

RESET

 

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROGRAM (OFF

 

ON, OFF

 

ON)

 

 

 

 

 

 

 

 

 

 

The indoor unit’s TIMER Indicator lamp (green) (Fig. 3 6) will light.

3

Use the SET TEMP.SET TIME button (Fig. 6 () to adjust

the desired OFF time or ON time.

Set the time while the time display is flashing (the flashing will continue for about five seconds).

button: Press to advance the time. button: Press to reverse the time.

About five seconds later, the entire display will reappear.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.

To Use the Program timer

1

Press the START/STOP button(Fig. 6 ¡).

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2

Set the desired times for OFF timer and ON timer.

 

See the section “To Use the ON Timer or OFF Timer” to set the desired mode

 

and times.

 

About three seconds later, the entire display will reappear.

3

The indoor unit’s TIMER Indicator Lamp (green) (Fig. 3 6) will light.

Press the TIMER button (Fig. 6 _) to select the PROGRAM

timer operation (either OFF = ON or OFF + ON will display).

The display will alternately show “OFF timer” and “ON timer”, then change to show the time setting for the operation to occur first.

÷ The PROGRAM timer will begin operation. (If the ON timer has been selected to operate first, the unit will stop operating at this point).

About five seconds later, the entire display will reappear.

About the Program timer

÷The PROGRAM timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

÷The first timer function to operate will be the one set nearest to the current time. The order of operation is indicated by the arrow in the Remote Control Unit’s display (OFF = ON, or OFF + ON).

÷One example of Program timer use might be to have the air conditioner automatically stop (OFF timer) after you go to sleep, then start (ON timer) automatically in the morning before you arise.

To Cancel the Timer

Use the TIMER button to select “TIMER RESET.”

The air conditioner will return to normal operation.

To Change the Timer Setting

1.Follow the instructions given in the section “To Use the ON Timer or OFF Timer” to select the timer setting you wish to change.

2.Press the TIMER button to select either OFF = ON or OFF + ON.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.

En-9

Image 11
Contents Page Timer Reset Safety Precautions Contents¶ Water leaking inside the unit could damage electrical PrecautionsDo not stay in direct cooling airflow for long periods Be careful to provide adequate ventilationDo not use inflammable gases near the air Conditioner Outlet portAutomatic Operation Features and FunctionsName of Parts Preparation Operation To Stop Operation Press the START/STOP button About Mode OperationTimer Operation During Cooling/Dry operation Sleep Timer OperationAbout the Sleep timer Right-Left Adjustment Adjust the Right-Left Louvers Adjusting the Direction of AIR CirculationAbout Swing Operation Swing OperationManual Auto Operation To Select Swing Operation Press the Swing Louver button £Inspections and Repairs Cleaning and CareCleaning the Indoor Unit Lock the Intake Grille Cleaning the Intake Grille Open the Intake GrilleClean with water Unlock the Intake GrilleReplace the Air Filter and close the Intake Grille Remove dust with a vacuum cleaner or by washingWhen using the optional Air Cleaning Filter Symptom Problem See Trouble ShootingOperation and Performance Event of Power InterruptionSymptom Items to Check Operating TipsOutdoor temperature Temperature and Humidity RangeCooling and Dry Mode Indoor temperature800 888-FGAI