Jet Tools J150ECA, J100ECA owner manual Removing Burner Head, 150,000 BTU/Hr Model

Page 15

Nozzle

(150,000 BTU/Hr Model)

1.Remove upper shell (see page 10).

2.Remove fan (see page 17).

3.Remove spark plug wire from spark plug.

4.Remove spark plug from burner head using 13/16" open-end wrench.

5.Loosen flare nut using 3/4" open-end wrench. Push fuel tube down.

6.Remove air line hose from burner head.

7.Remove three screws using 5/16" nut-driver and remove burner head from combustion chamber.

8.Place burner head into vise and lightly tighten.

9.Carefully remove nozzle from burner head using 5/8" socket wrench (see Figure 17).

10.Blow compressed air thru face of nozzle. This will free any dirt in nozzle area.

11.Inspect nozzle seal for damage.

12.Replace nozzle into burner head and tighten firmly

(80-110 inch-pounds/9.1-

12.4 n-m).

13.Attach burner head to combustion chamber.

14.Install spark plug in burner head.

15.Attach spark plug wire to spark plug.

16.Attach fuel tube and airline hose to burner head. Attach flare nut until nut seats against fuel tube and fitting. Tighten 1/4 turn more using 3/4" open-end wrench (100-130 inch- pounds/11.3-14.7 n-m).

17.Replace fan (see page 17).

18.Replace fan guard and upper shell.

Combustion

Chamber

 

Spark Plug

Burner Head

Wire

Screw

Spark

Plug

Air Line Hose

Flare Nut

Fuel Tube

Figure 16 - Removing Burner Head, 150,000 BTU/Hr Model

Nozzle

Face

Nozzle

Seal

Nozzle

Burner

Head

Figure 17 - Removing Nozzle, 150,000 BTU/Hr Model

15

Image 15
Contents Portable Forced AIR Heaters Contents Carbon monoxide poisoning may lead to death Safety Information100,000 BTU/Hr Model Product IdentificationTools Needed Unpacking AssemblyTheory OperationFuels To Restart Heater Ventilation OperationTo Start Heater To Stop HeaterStorage Preventative Maintenance Schedule TROUBLE- Shooting Observed FaultUpper Shell Removal Service ProceduresFuel Filter Removal, 100,000 BTU/Hr Model Fuel FilterSpark Plug Removal Spark PlugAir Output, Air Intake, and Lint Filters Pump Pressure AdjustmentRemoving Burner Head, 100,000 BTU/Hr Model NozzleRemoving Burner Head, 150,000 BTU/Hr Model Rotor Location Pump RotorFan, Motor Shaft, and Setscrew Location FanAccessory Wiring DiagramWheels and Handles 100,000 BTU/Hr Model Parts BreakdownKEY Part Number Description QTY Parts List150,000 BTU/Hr Model IllustratedNPC-4C Warranty and Repair Service