Fan

IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch.

1.Remove upper shell (see page 10).

2.Use 1/8" Allen wrench to loosen setscrew which holds fan to motor shaft.

3.Slip fan off motor shaft.

4.Clean fan using a soft cloth moistened with kerosene or solvent.

5.Dry fan thoroughly.

6.Replace fan on motor shaft. Place fan hub flush with end of motor shaft (see Figure 22).

7.Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds/ 4.5-5.6 n-m).

8.Replace fan guard and upper shell.

Setscrew

Fan

Motor

Shaft

Figure 21 - Fan, Motor Shaft, and Setscrew Location

Fan

Flush

Motor Shaft

Setscrew

Figure 22 - Fan Cross Section

17

Image 17
Contents Portable Forced AIR Heaters Contents Carbon monoxide poisoning may lead to death Safety Information100,000 BTU/Hr Model Product IdentificationTools Needed Unpacking AssemblyFuels TheoryOperation To Start Heater Ventilation OperationTo Stop Heater To Restart HeaterStorage Preventative Maintenance Schedule TROUBLE- Shooting Observed FaultUpper Shell Removal Service ProceduresFuel Filter Removal, 100,000 BTU/Hr Model Fuel FilterSpark Plug Removal Spark PlugAir Output, Air Intake, and Lint Filters Pump Pressure AdjustmentRemoving Burner Head, 100,000 BTU/Hr Model NozzleRemoving Burner Head, 150,000 BTU/Hr Model Rotor Location Pump RotorFan, Motor Shaft, and Setscrew Location FanAccessory Wiring DiagramWheels and Handles 100,000 BTU/Hr Model Parts BreakdownKEY Part Number Description QTY Parts List150,000 BTU/Hr Model IllustratedNPC-4C Warranty and Repair Service