Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spark Plug

 

 

 

 

 

 

Terminal

 

 

 

 

 

 

 

 

 

 

Ignitor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120V 60Hz

 

 

 

 

 

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green/Yellow

 

 

 

 

 

 

 

 

 

 

 

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

Relay

Red

 

 

 

 

 

 

Brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Rating (BTU/Hr)

100,000

150,000

Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity

 

 

(U.S. Gal./Liters)

9/34

13.5/51

Fuel Consumption

 

 

(Gal. Per Hr./Liters Per Hr.)

.74/2.8

1.10/4.16

Electric Requirements

120 volt/60 hertz

120 volt/60 hertz

Amperage (Normal Run)

4.5

4.5

Hot Air Output (CFM/CMM)

480/13.6

648/18.3

RPM

3450

3450

AIR GAUGE KIT - HA1180

Special tool to check pump pressure.

Image 18
Contents Portable Forced AIR Heaters Contents Safety Information Carbon monoxide poisoning may lead to deathProduct Identification 100,000 BTU/Hr ModelUnpacking Assembly Tools NeededTheory OperationFuels To Stop Heater Ventilation OperationTo Start Heater To Restart HeaterStorage Preventative Maintenance Schedule Observed Fault TROUBLE- ShootingService Procedures Upper Shell RemovalFuel Filter Fuel Filter Removal, 100,000 BTU/Hr ModelSpark Plug Spark Plug RemovalPump Pressure Adjustment Air Output, Air Intake, and Lint FiltersNozzle Removing Burner Head, 100,000 BTU/Hr ModelRemoving Burner Head, 150,000 BTU/Hr Model Pump Rotor Rotor LocationFan Fan, Motor Shaft, and Setscrew LocationWiring Diagram AccessoryWheels and Handles Parts Breakdown 100,000 BTU/Hr ModelParts List KEY Part Number Description QTYIllustrated 150,000 BTU/Hr ModelNPC-4C Warranty and Repair Service