2.2.1Standard connection diagram 1 - sink (common: CC)

E6580757

2.2.1Standard connection diagram 1 - sink (common: CC)

This diagram shows a standard wiring of the main circuit.

 

Main circuit power supply

 

200V class: single-phase 200 ~ 240V-50/60Hz

 

three-phase 200 ~ 230V-50/60Hz

2

400V class: three-phase 380 ~ 500V-50/60Hz

 

DC reactor (DCL)

*2 (option)VF-S9Manual background Braking resistor (option)

P0 PA PB PC

MCCB R/L1

S/L2

Filter Main circuit

U/T1

V/T2

Motor

IM

T/L3

*1

W/T3

Control

F

Forward

Power supply

MCCB(2P)

R/L1

1φ 200 ~ 240V

 

-50/60Hz

S/L2

 

*1 1-phase series don't have T/L3 terminal.

*2 The PO-PA terminals are shorted by a bar when shipped from the factory. Before installing the DC reactor (DCL), remove the bar.

Fault detection relay

FLC

circuit

 

R

 

 

FLB

VF-S9

RST

 

S1

FLA

Operation panel

 

 

S2

 

 

Connector for

 

 

 

RY

 

common serial

S3

 

communications

Manual background Reverse

Manual background Reset

Manual background Preset speed1

Manual background Preset speed2

Manual background Preset speed3

Low-speed detection signal

RC

FMV

SOURCE

CC

 

JP301A

JP301

I I

JP302

P24

 

FMC

SINK

OUT

Common

Current signal:

+

4 ~ 20mA

 

 

 

 

 

Designated frequency

 

 

Ry

 

 

attainment signal

 

 

 

 

 

 

 

 

 

 

FM

CC VIA

Meter +

VIB PP

+

Frequency

meter

-

Voltage signal: 0 ~ 10V

-

External potentiometer

(or input voltage signal across VIA-CC terminals: 0 ~ 10V) *The VIA terminal and II terminal

cannot be used at the same time.

B-4

Page 35
Image 35
Toshiba VF-S9 manual Standard connection diagram 1 - sink common CC