E6580757
Note 4
Note 4
Note 4
Note 4
Note 5
8
(Continued)
Item displayed | Key | LED | Communi- | Description | |
operated | display | cation No. | |||
|
| ||||
|
|
|
|
| |
CPU version |
|
| FE08 | The version of the CPU is displayed. | |
|
|
|
|
| |
Memory version |
|
| FE09 | The version of the memory mounted is displayed. | |
|
|
|
|
| |
Past trip 1 |
|
| FE10 | Past trip 1 (displayed alternately at | |
|
| vals) | |||
|
|
|
| ||
Past trip 2 |
|
| FE11 | Past trip 2 (displayed alternately at | |
|
| vals) | |||
|
|
|
| ||
Past trip 3 |
|
| FE12 | Past trip 3 (displayed alternately at | |
|
| vals) | |||
|
|
|
| ||
Past trip 4 |
|
| FE13 | Past trip 4 (displayed alternately at | |
|
| vals) | |||
|
|
|
| ||
Cumulative |
|
| FE14 | The cumulative operation time is displayed. (0.01 | |
operation time |
|
| corresponds to 1 hours.) | ||
|
|
| |||
Torque current |
|
| FE20 | The torque current is displayed in %. | |
|
|
|
|
| |
PI feedback |
|
| FE22 | The PI feedback value is displayed. | |
|
| (Unit: processed amount) | |||
|
|
|
| ||
Inverter load factor |
|
| FE26 | The inverter load factor is displayed in %. | |
|
|
|
|
| |
PBR overload |
|
| FE28 | The overload factor of the braking resistor is dis- | |
factor |
|
| played in %. | ||
|
|
| |||
Output power |
|
| FE30 | The inverter output power is displayed in %. | |
|
|
|
|
| |
Default display |
|
|
| The operation frequency is displayed | |
mode |
|
|
| (during operation). |
Note 1: Press the or key to change items displayed in the status monitor mode.
Note 2: With the current unit selection parameter or voltage unit selection parameter, you can choose between
| percentage and ampere (A) for current or between percentage and volt (V) for voltage, respectively. |
Note 3: | The input (DC) voltage displayed is 1/ 2 times as large as the rectified dc input voltage. |
Note 4: | is displayed to show the absence of error. |
Note 5: The cumulative operation time increments only when the machine is in operation.