Toshiba VF-S9 manual Table of parameters and data, User parameters, Basic parameters, Other

Models: VF-S9

1 198
Download 198 pages 1.97 Kb
Page 168
Image 168
11.Table of parameters and data

E6580757

11.Table of parameters and data

11.1User parameters

*1 : The end of type – form depend

 

 

 

 

 

 

AN – WN : 60Hz

 

 

 

 

 

 

 

WP : 50Hz

 

 

 

 

 

 

*2 : Model depend (See section 11 page K-6)

Title

Function

Unit

Minimum

Adjustment range

Default

 

User

Reference

 

 

 

setting unit

 

setting

 

setting

 

 

 

 

 

 

 

 

 

 

-

Applicable motor

Hz

-

60

*1

 

 

4.1

 

base frequency *3

 

 

50

 

 

 

 

 

Operation

Hz

0.1

-

0.0

 

 

3.2

 

frequency of

 

 

 

 

 

 

 

 

operation panel

 

 

 

 

 

 

 

*3 : When the standard setting ( 11.1User parameters : 11.2Basic parameters ) is entered, this parameter displayed.

11.2Basic parameters

Four automatic functions

Title

Communication

Function

Unit

Minimum

Adjustment range

Default

User

Reference

 

 

 

 

No.

 

 

setting unit

 

setting

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0000

Automatic

-

-

0: Disabled (manual)

0

 

5.1

 

 

 

 

 

acceleration/

 

 

1: Optimum rate

 

 

 

 

 

 

 

 

deceleration

 

 

2: Minimum rate

 

 

 

 

 

 

 

0001

Automatic torque

-

-

0: Disabled

0

 

5.2

 

 

 

 

 

boost

 

 

1: Vector control + auto-tuning

 

 

 

 

 

 

 

0002

Automatic

-

-

0: Disabled

0

 

5.3

 

 

 

 

 

environment

 

 

1: Automatic setting

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

 

 

 

 

 

0040

Automatic function

-

-

0: Disabled

0

 

5.4

 

 

 

 

 

setting

 

 

1: Coast stop

 

 

 

 

 

 

 

 

 

 

 

2: 3-wire operation

 

 

 

 

 

 

 

 

 

 

 

3: External input UP/DOWN setting

 

 

 

 

 

 

 

 

 

 

 

4: 4-20 ma current input operation

 

 

 

 

 

 

Other

basic parameters

 

 

 

 

 

 

 

Title

Communication

Function

Unit

Minimum

Adjustment range

Default

User

Reference

 

 

 

 

No.

 

 

setting unit

 

setting

setting

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

0003

Command mode

-

-

0: Terminal board

1

 

5.5

 

 

 

 

selection

 

 

1: Operation panel

 

 

 

 

 

 

0004

Frequency setting

-

-

0: Terminal board

2

 

5.5

 

 

 

 

 

 

 

 

 

mode selection

 

 

1: Operation panel

 

 

 

 

 

 

 

 

 

 

 

2: Internal potentiometer

 

 

 

 

 

 

 

0005

Meter selection

-

-

0: Output frequency

0

 

5.6

 

 

 

 

 

 

 

 

1: Output current

 

 

 

 

 

 

 

 

 

 

 

2: Set frequency

 

 

 

 

 

 

 

 

 

 

 

3: For adjustment (current fixed at

 

 

 

 

 

 

 

 

 

 

 

100%)

 

 

 

 

 

 

 

 

 

 

 

4: Inverter load factor

 

 

 

 

 

 

 

 

 

 

 

5: Output power

 

 

 

 

 

 

 

0006

Meter adjustment

-

-

 

-

 

5.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0007

Standard setting

-

-

0 2: -(invalid)

0

 

5.7

 

 

 

 

 

mode selection

 

 

3: Default setting

 

 

 

 

 

 

 

 

 

 

 

4: Trip clear

 

 

 

 

 

 

 

 

 

 

 

5: Cumulative operation time clear

 

 

 

 

 

 

 

 

 

 

 

6: Initialization of type information

 

 

 

 

 

K-1

Page 168
Image 168
Toshiba VF-S9 manual Table of parameters and data, User parameters, Basic parameters, Four automatic functions, Other