Toshiba VF-S9 manual Extended parameters, Input/output parameters

Models: VF-S9

1 198
Download 198 pages 1.97 Kb
Page 169
Image 169
11.3 Extended parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

E6580757

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

Communication

Function

Unit

Minimum

 

Adjustment range

 

Default

User

 

Reference

 

 

No.

 

 

setting unit

 

 

 

 

 

setting

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0008

Forward/reverse

-

-

0: Forward run

 

 

0

 

 

5.8

 

 

 

 

run selection

 

 

1: Reverse run

 

 

 

 

 

 

 

 

 

 

(Operation panel)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0009

Acceleration

s

0.1

0.1-3600

 

 

 

10.0

 

 

5.1

 

 

 

 

time 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0010

Deceleration

s

0.1

0.1-3600

 

 

 

10.0

 

 

5.1

 

 

 

 

time 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0011

Maximum

Hz

0.1

30.0-400

 

 

 

80.0

 

 

5.9

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0012

Upper limit

Hz

0.1

0.5-

 

 

 

 

*1

 

 

5.10

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00013

lower limit

Hz

0.1

0.0-

 

 

 

 

0.0

 

 

5.10

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0014

Base frequency 1

Hz

0.1

25-400

 

 

 

60.0 *1

 

 

5.11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0015

V/F control mode

-

-

0: V/F constant

 

 

0

 

 

5.12

 

 

 

 

selection

 

 

1: Variable torque

 

 

 

 

 

 

 

 

 

 

 

 

2: Automatic torque boost

 

 

 

 

 

 

 

 

 

 

 

 

3: Sensorless Vector control

 

 

 

 

 

 

 

 

 

 

 

 

4: Automatic energy-saving

 

 

 

 

 

 

 

 

0016

Torque boost

%/(V)

0.1

0.0-30.0

 

 

 

*2

 

 

5.13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0041

Motor

%/(A)

1

10-100

 

 

 

100

 

 

5.14

 

 

 

 

electronic-thermal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

protection level 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0017

Electronic-thermal

-

-

Setting

type

 

Overload protection

OL stall

0

 

 

5.14

 

 

 

 

protection

 

 

0

 

 

{

 

 

 

 

 

 

 

 

characteristic

 

 

1

Standard

 

{

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

selection *4

 

 

2

motor

 

 

 

 

 

 

 

 

 

 

 

3

 

 

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

VF motor

 

{

 

 

 

 

 

 

 

 

 

 

 

5

 

{

{

 

 

 

 

 

 

 

 

 

 

 

(special

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

motor)

 

 

 

 

 

 

 

 

 

 

 

 

7

 

{

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0018

Preset-speed

Hz

0.1

-

 

 

 

 

0.0

 

 

5.15

 

 

to

to

operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0024

frequencies 1 to 7

 

 

 

 

 

 

 

 

 

 

 

 

 

____

-

Extended

-

-

-

 

 

 

 

-

-

 

4.1

 

 

 

 

parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

Automatic edit

-

-

-

 

 

 

 

-

-

 

4.1

 

 

 

 

function

 

 

 

 

 

 

 

 

 

 

 

 

*4 : { : valid, : invalid

11

11.3 Extended parameters

Input/output parameters

Title

Communication

Function

Unit

Minimum

Adjustment range

Default

User

Reference

 

No.

 

 

setting unit

 

setting

setting

 

 

 

 

 

 

 

 

 

 

0100

Low-speed signal

Hz

0.1

0.0-

0.0

 

6.1.1

 

 

output frequency

 

 

 

 

 

 

 

0101

Speed reach

Hz

0.1

0.0-

0.0

 

6.1.3

 

 

setting frequency

 

 

 

 

 

 

 

0102

Speed reach

Hz

0.1

0.0-

2.5

 

6.1.2

 

 

detection band

 

 

 

 

 

 

 

0103

ST signal

-

-

0: Stand by on when ST is on

1

 

6.2.1

 

 

selection

 

 

1: Stand by always on

 

 

 

 

 

 

 

 

2: Interlocked with F/R

 

 

 

 

 

 

 

 

3: Stand by on when ST is off

 

 

 

 

0104

RST signal

-

-

0: Default

0

 

6.2.2

 

 

selection

 

 

1: Activated by turning RST off

 

 

 

K-2

Page 169
Image 169
Toshiba VF-S9 manual Extended parameters, Input/output parameters