6. Extended parameters

E6580757

6. Extended parameters

Extended parameters are provided for sophisticated operation, fine adjustment and other special purposes. Modify pa- rameter settings as required. See Section 11, Table of extended parameters.

6.1Input/output parameters

6.1.1Low-speed signal

: Low-speed signal output frequency

Function

 

 

 

 

 

 

When the output frequency exceeds the setting of this parameter, an ON signal will be generated. This

 

 

signal can be used as an electromagnetic brake excitation/release signal.

 

 

Relay output (250Vac-2A (cos φ = 1), 30Vdc-1A, 250Vac -1A (cos φ

= 0.4) at RY-RC or FLA-FLC-

 

 

FLB terminals (Default setting: RY-RC).

 

 

 

 

 

 

 

 

 

 

6

 

Open-collector output (24Vdc-50mA [maximum]) can also be set at OUT terminal.

 

 

[Parameter setting]

 

 

 

 

 

 

 

 

 

 

Title

 

Function

Adjustment range

 

Default setting

 

 

 

 

 

 

 

 

 

 

 

Low-speed signal output frequency

0.0 (Hz)

 

0.0

 

 

Output frequency [Hz]

Set frequency

Time [sec]

Low-speed signal output

RY-RC terminals (Default setting)

P24-OUT terminals

FLA-FLC-FLB terminals

Low-speed signal output: Inverted