Toshiba VF-S9 manual Order of precedence of combined functions

Models: VF-S9

1 198
Download 198 pages 1.97 Kb
Page 179
Image 179
■Order of precedence of combined functions

E6580757

Order of precedence of combined functions

XX: Impossible combination, X: Invalid, +: Valid under some conditions, O: Valid, @: Priority

 

Function No. / Function

2

3

4

5

6-9

10

11

12

13

14

15

46

48

41/

43

49

38

50/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

 

 

 

51

2

Forward run command

 

X

O

O

O

O

X

O

X

O

O

X

O

O

O

O

O

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Reverse run command

@

 

O

O

O

O

X

O

X

O

O

X

O

O

O

O

O

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Jog run command (18/19)

+

+

 

@

+

O

X

O

X

@

O

X

O

+

O

XX

O

XX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Acceleration/deceleration 2 selection

O

O

X

 

O

O

X

O

X

O

O

X

O

O

O

O

O

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6~9

Preset-speed run commands 1 to 4

O

O

X

O

 

O

X

O

X

O

O

X

O

O

O

O

O

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Reset command

O

O

O

O

O

 

X

O

O

O

O

X

O

O

O

O

O

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Trip stop command from external input

@

@

@

@

@

@

 

O

@

@

O

X

O

@

O

@

O

@

 

device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Operation panel/terminal board switching

O

O

O

O

O

O

O

 

O

O

O

O

O

O

O

O

O

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

DC braking command

@

@

@

@

@

O

X

O

 

@

O

X

O

@

O

@

O

@

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

PI control prohibition

O

O

X

O

O

O

X

O

X

 

O

X

O

XX

XX

O

O

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

Permission of parameter editing

O

O

O

O

O

O

O

O

O

O

 

O

O

O

O

O

O

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

46

Thermal trip stop command from external

@

@

@

@

@

@

@

O

@

@

O

 

O

@

O

@

O

@

 

device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

Remote/local control forced switching

O

O

O

O

O

O

O

O

O

O

O

O

 

O

O

O

O

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41/

Frequency UP/DOWN signal input from

O

O

X

O

O

O

X

O

X

XX

O

X

O

 

O

O

O

O

42

external contacts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

Clearing of UP/DOWN frequency with

O

O

O

O

O

O

O

O

O

XX

O

O

O

O

 

O

O

O

 

external contacts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

49

Operation holding

O

O

XX

O

O

O

X

O

X

O

O

X

O

O

O

 

O

XX

 

(cancellation of 3-wire operation)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

Frequency commands forced switching

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50/

Operation command after DC braking

+

+

XX

O

O

O

X

O

X

O

O

X

O

O

O

XX

O

 

51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* For the functions of combined terminals (combined functions), refer to the table of their respective functions.