Toshiba VF-S9 manual 5cm 5cm

Models: VF-S9

1 198
Download 198 pages 1.97 Kb
Page 28
Image 28
5cm

E6580757

Do not install in any location of high temperature, high humidity, moisture condensation and freezing and avoid locations where there is exposure to water and/or where there may be large amounts of dust, metallic fragments and oil mist.

Do not install in any location where corrosive gases or grinding

 

fluids are present.

 

 

 

 

Operate in areas where ambient temperature ranges from -10°C to 60° C.

1

 

(Operation over 40° C is allowed when peel off the top warning label. And operation over 50° C is al-

lowed when reduce to 70° C or less of rated current.)

5cm

5cm

5cm

Measurement position

Measurement position

Note: The inverter is a heat-emitting body. Make sure to provide proper space and ventilation when install- ing in the cabinet. When installing inside a cabinet, we recommend peel of the top seal although 40° C or less.

Do not install in any location that is subject to large amounts of vibration.

Note:

If the VF-S9 Inverter is installed in a location that is subject

 

to vibration, anti-vibration measures are required. Please

 

consult with Toshiba about these measures.

If the VF-S9 Inverter is installed near any of the equipment listed below, provide measures to insure against errors in operation.

Solenoids:

Attach surge suppressor on coil.

Brakes:

Attach surge suppressor on coil.

Magnetic contactors:

Attach surge suppressor on coil.

Fluorescent lights:

Attach surge suppressor on coil.

Resistors:

Place far away from VF-S9 Inverter.