E6580757

6.6Operation frequency

6.6.1Starting frequency

: Starting frequency setting

Function

 

 

 

 

The frequency set with the parameter

is put out immediately on completion of frequency set-

ting.

 

 

 

 

Use the

parameter when a delay in response of starting torque according to the accelera-

tion/deceleration time is probably affecting operation. Setting the starting frequency to a value from 0.5

to 2Hz (maximum: 5Hz) is recommended. The occurrence of an overcurrent can be suppressed by

setting this frequency below the rated slippage of the motor.

 

[Parameter setting]

 

 

 

 

Title

 

Function

 

Adjustment range

Default setting

 

 

 

 

 

 

Starting frequency setting

 

0.5 10.0 (Hz)

0.5

Output frequency [Hz]

6

 

 

 

Starting frequency setting

Time [sec]

F-17

Page 101
Image 101
Toshiba VF-S9 Operation frequency, Starting frequency setting, Function Frequency set with the parameter, Ting Use