6.6Operation frequency
6.6.1Starting frequency
: Starting frequency setting
• Function |
|
|
|
| |
The frequency set with the parameter | is put out immediately on completion of frequency set- | ||||
ting. |
|
|
|
| |
Use the | parameter when a delay in response of starting torque according to the accelera- | ||||
tion/deceleration time is probably affecting operation. Setting the starting frequency to a value from 0.5 | |||||
to 2Hz (maximum: 5Hz) is recommended. The occurrence of an overcurrent can be suppressed by | |||||
setting this frequency below the rated slippage of the motor. |
| ||||
[Parameter setting] |
|
|
|
| |
Title |
| Function |
| Adjustment range | Default setting |
|
|
|
|
| |
| Starting frequency setting |
| 0.5 ∼ 10.0 (Hz) | 0.5 |
Output frequency [Hz] | 6 |
| |
|
|
Starting frequency setting
Time [sec]