6.6Operation frequency

E6580757

6.6Operation frequency

6.6.1Starting frequency

6.6.1Starting frequency : Starting frequency setting

Function

 

 

 

 

The frequency set with the parameter

is put out immediately on completion of frequency set-

ting.

 

 

 

 

Use the

parameter when a delay in response of starting torque according to the accelera-

tion/deceleration time is probably affecting operation. Setting the starting frequency to a value from 0.5

to 2Hz (maximum: 5Hz) is recommended. The occurrence of an overcurrent can be suppressed by

setting this frequency below the rated slippage of the motor.

 

[Parameter setting]

 

 

 

 

Title

 

Function

 

Adjustment range

Default setting

 

 

 

 

 

 

Starting frequency setting

 

0.5 10.0 (Hz)