3.2.1How to start and stop

E6580757

3.2.1How to start and stop

(1) Start and stop using the operation panel keys ( (1) Start and stop using the operation panel keys (  ) )

Use the

and

keys on the operation panel to start and stop the motor.

 

RUN: Motor starts.

(2) Start and stop using external signals to the terminal board (  ) STOP: Motor stops (slowdown stop).

(2) Start and stop using external signals to the terminal board ( Short F and CC terminals: run forward )

Use external signals to the inverter terminal board to start and stop the motor. (Set JP301 to sink logic)

Short F and CC terminals: run forward

* Coast stop

3

Open F and CC terminals:

slow down and stop

The standard default setting is for slowdown stop. To make a coast stop, assign an ST terminal function to an idle terminal using the programmable terminal

function. And set the Open F and CC terminals: :ST signal selection. For coast stop, open the ST-CC when stopping the motor in the state described at left. The monitor on

the inverter at this time will display 3.2.2How to set the frequency .

Motor speed

Coast stop

Frequency

F-CC

 

 

Slowdown stop

F-CC

 

 

 

 

 

 

 

ON

ST-CC

 

 

 

OFF

 

 

 

 

 

3.2.2How to set the frequency

(1)Setting the frequency using the potentiometer on the inverter main unit

(Manual background )

Set the frequency with the notches on the potentiometer.

Move clockwise through the higher notches for the higher frequencies.