E6580757
6.6.2Run/stop control with frequency setting signals
: Operation starting frequency
: Operation starting frequency hysterisis
• Function
The Run/stop of operation can be controlled simply with frequency setting signals.
[Parameter setting]
Title | Function |
| Adjustment range | Default setting |
|
|
|
|
|
| Operation starting frequency | 0.0 ∼ | (Hz) | 0.0 |
| Operation starting frequency hysterisis | 0.0 ∼ | (Hz) | 0.0 |
Output frequency [Hz]
6
The inverter begins accelerating after the frequency setting signal has reached point B. Deceleration begins when the frequency setting signal decreases below point A.
Frequency command value
6.7DC braking
6.7.1DC braking
: DC braking starting frequency
: DC braking current : DC braking time
• Function
A large braking torque can be obtained by applying a direct current to the motor. These parameters set the direct current to be applied to the motor, the application time and the starting frequency.