: Set the slip frequency for the motor. A higher slip frequency reduces motor slipping correspond-

 

 

E6580757

 

 

 

Setting procedure

 

 

Adjust the following parameters:

 

: Select "

" to set the motor constant independently using the parameters.

: Set the slip frequency for the motor. A higher slip frequency reduces motor slipping correspond-

ingly. (The slip frequency can be set on the basis of test records of the motor.)

 

: Adjust the primary resistive component of the motor. Decreases in torque due to a possible volt-

age drop during low-speed operation can be suppressed by setting a large value in this parameter.

(Perform adjustments according to the actual operation.)

 

: Adjust the secondary component of the motor. This parameter is enabled only when

is

set to "

". A larger adjustment value gives more slip correction. (Perform adjustments according

to the actual operation.)

 

: Set the excitation inductance for the motor. A larger inductance creates a smaller no-load current.

(Perform adjustments according to the actual operation.)

Manual background : Set a load inertia moment with a multiple of the motor inertia moment. A transient response can be adjusted. A larger adjustment value reduces inertial overshoot, and thus prevents the occur- rence of an overcurrent and an overvoltage, correspondingly.

Manual background : Set "1" if the rated capacity of the motor is one size smaller than that of the inverter.

6

* Sensorless vector control may not operate properly if the motor capacity differs from the appli-

cable rated capacity of the inverter by more than two grades.

 

F-38

Page 122
Image 122
Toshiba VF-S9 manual Set the slip frequency for the motor. A higher slip frequency reduces motor slipping correspond