■Table of input terminal functions (3/3)

E6580757

Table of input terminal functions (3/3)

Function

Code

Function

 

 

Action

 

No.

 

 

 

 

 

 

45

EXTN

Inversion of trip stop command from external de-

OFF:

-trip stop

 

 

 

 

vice

 

 

 

 

46

OH

Thermal trip stop signal input from external device

ON: trip stop

 

 

47

OHN

Inversion of thermal trip stop command from ex-

OFF:

trip stop

 

 

 

 

ternal device

 

 

 

 

48

SC/LC

Remote/local control forced switching

Enabled when remote control is exercised

 

 

 

ON: Local control

 

 

 

 

 

(setting of

and

)

 

 

 

OFF: Remote control

 

 

49

HD

Operation holding (stop of 3-wire operation)

ON: F (forward run)/R: (reverse run) held, 3-wire

 

 

 

operation

 

 

 

 

 

OFF: Slowdown stop

 

 

50

SDBF

Forward run after DC braking

ON: Forward run after DC braking

 

 

 

 

OFF: Slowdown stop

 

 

51

SDBR

Reverse run after DC braking

ON: Reverse run after DC braking

 

 

 

 

OFF: Slowdown stop

 

 

Table of output terminal functions (1/2)

 

 

Function

Code

Function

 

Action

 

 

 

No.

 

 

 

 

 

 

 

0

LL

Frequency lower limit

ON: Output frequency is equal to or higher than

 

 

 

 

 

 

value.

 

 

 

 

 

 

OFF: Output frequency is lower than

 

 

 

 

 

 

 

value.

 

 

 

1

LLN

Inversion of frequency lower limit

Inversion of LL setting

 

 

 

2

UL

Frequency upper limit

ON: Output frequency is equal to or higher than

 

 

 

 

 

 

value.

 

 

 

 

 

 

OFF: Output frequency is lower than

 

 

 

 

 

 

 

value.

 

 

 

3

ULN

Inversion of frequency upper limit

Inversion of UL setting

 

 

 

4

LOW

Low-speed detection signal

ON: Output frequency is equal to or higher than

 

 

 

 

 

 

set value.

 

 

 

 

 

 

OFF: Output frequency is lower than

 

 

 

 

 

 

 

set value.

 

 

 

5

LOWN

Inversion of low-speed detection signal

Inversion of LOW setting

 

 

 

6

RCH

Designated frequency reach signal (completion of

ON: Output frequency is within (input frequency

 

 

 

 

acceleration/deceleration)

±

set frequency).

 

 

 

 

 

 

OFF: Output frequency exceeds (input frequency

 

 

 

 

 

±

set frequency).

 

 

 

 

 

 

 

 

 

7

RCHN

Inversion of designated frequency reach signal

Inversion of RCH setting

 

11

 

 

 

(inversion of completion of acceleration/

 

 

 

 

 

 

deceleration)

 

 

 

 

8

RCHF

Set frequency reach signal

ON: Output frequency is within

 

 

 

 

 

 

(

set frequency ±

set

 

 

 

 

 

frequency).

 

 

 

 

 

 

OFF: Output frequency exceeds

 

 

 

 

 

 

(

set frequency ±

set

 

 

 

 

 

frequency).

 

 

 

9

RCHFN

Inversion of set frequency reach signal

Inversion of RCHF setting

 

 

 

10

FL

Failure FL (trip output)

ON: When inverter is tripped

 

 

 

 

 

 

OFF: When inverter is not tripped

 

 

 

11

FLN

Inversion of failure FL (inversion of trip output)

Inversion of FL setting

 

 

 

12

OT

Over-torque detection

ON: Torque current is equal to or larger than

 

 

 

 

 

set value and longer than

set time.

 

 

 

 

 

OFF: Torque current is lower than

set

 

 

 

 

 

value.

 

 

 

13

OTN

Inversion of over-torque detection

Inversion of OT setting

 

 

 

14

RUN

RUN/STOP

ON: When operation frequency is output or during

 

 

 

 

 

DC braking ( )

 

 

 

 

 

 

OFF: Operation stopped

 