Setting
4 (ON signal)
or
5 (OFF signal)
Adjustment range

E6580757

[Connection diagram for sink logic]

[Incase of relay]

Ry

P24

OUT

Ry

RC

RY

Output terminal setting Output of the low-speed signal (ON signal) between the RY and RC terminals is the factory default set- ting of the output terminal selection parameter. This setting must be changed to invert the polarity of the signal. [Parameter setting]

TitleFunction

Output terminal selection 1 (RC-RY)

0 29

(see section 11)

6

If the signal output from OUT terminal, set

to the value.

 

 

6.1.2Output of designated frequency reach signal

: Speed reach detection band

Function

When the output frequency becomes equal to the designated frequency the setting of this parameter, an ON or OFF signal is generated.

Parameter setting of designated frequency and detection band

Title

Function

 

Adjustment range

Default setting

 

 

 

 

 

 

Speed reach detection band

0.0

(Hz)

2.5

Parameter setting of output terminal selection

Title

Function

Adjustment range

Setting

 

 

 

 

 

Output terminal

0 29

6: RCH (Designated frequency - ON signal),

 

or

 

selection 2 (OUT)

(See section 11)

 

7: RCH (Designated frequency - OFF signal)

 

 

 

Note: Select the parameter to specify RY-RC terminal output, or the parameter to specify FLA-FLC-FLB terminal output.

F-2