Toshiba VF-S9 manual Operation mode parameters, E6580757

Models: VF-S9

1 198
Download 198 pages 1.97 Kb
Page 172
Image 172
•Operation mode parameters

E6580757

Operation mode parameters

Title

Communication

Function

Unit

Minimum

Adjustment range

Default

User

Reference

 

 

 

No.

 

 

setting unit

 

setting

setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0300

PWM carrier

kHz

0.1

2.0-16.5

12.0

 

6.11

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

0301

Auto-restart

-

-

0: Disabled

0

 

6.12.1

 

 

 

 

control selection

 

 

1: At auto-restart after momentary stop

 

 

 

 

 

 

 

 

 

 

2: When turning ST-CC on or off

 

 

 

 

 

 

 

 

 

 

3: At auto-restart or when turning

 

 

 

 

 

 

 

 

 

 

ST-CC on or off

 

 

 

 

 

 

 

 

 

 

4: Motion of DC braking at start-up

 

 

 

 

 

 

 

 

 

 

(at auto-restart after momentary

 

 

 

 

 

 

 

 

 

 

stop)

 

 

 

 

 

 

 

 

 

 

5: Motion of DC braking at start-up

 

 

 

 

 

 

 

 

 

 

(when turning ST-CC on or off)

 

 

 

 

 

 

 

 

 

 

6: Motion of DC braking at start-up

 

 

 

 

 

 

 

 

 

 

(at auto-restart or when turning

 

 

 

 

 

 

 

 

 

 

ST-CC on or off)

 

 

 

 

 

 

0302

Regenerative

-

-

0: Disabled

0

 

6.12.2

 

 

 

 

power ride-

 

 

1: Enabled

 

 

 

 

 

 

 

through control

 

 

 

 

 

 

 

 

 

0303

Retry selection

Times

1

0-10

0

 

6.12.3

 

 

 

 

(number of times)

 

 

 

 

 

 

 

 

 

0304

Dynamic braking

-

-

0: Dynamic braking disabled

0

 

6.12.4

 

 

 

 

selection

 

 

1: Dynamic braking enabled, over-

 

 

 

 

 

 

 

 

 

 

load protection disabled

 

 

 

 

 

 

 

 

 

 

2: Dynamic braking enabled, over-

 

 

 

 

 

 

 

 

 

 

load protection enabled

 

 

 

 

 

 

0305

Overvoltage limit

-

-

0: Enabled

0

 

6.12.5

 

 

 

 

operation

 

 

1: Prohibited

 

 

 

 

 

 

0306

Output voltage

V

1

0 to 250V, 0 to 500V

200V/400V

 

6.12.6

 

 

 

 

adjustment (Base

 

 

 

 

 

 

 

 

 

 

frequency voltage)

 

 

 

 

 

 

 

 

 

0307

Supply voltage

-

-

0: Supply voltage uncorrected, output

1

 

6.12.6

 

 

 

 

correction

 

 

voltage limited

 

 

 

 

 

 

 

 

 

 

1: Supply voltage corrected, output

 

 

 

 

 

 

 

 

 

 

voltage limited

 

 

 

 

 

 

 

 

 

 

2: Supply voltage corrected (off dur-

 

 

 

 

 

 

 

 

 

 

ing deceleration), output voltage

 

 

 

 

 

 

 

 

 

 

limited

 

 

 

 

 

 

 

 

 

 

3: Supply voltage uncorrected, output

 

 

 

 

 

 

 

 

 

 

voltage unlimited

 

 

 

 

 

 

 

 

 

 

4: Supply voltage corrected, output

 

 

 

 

 

 

 

 

 

 

voltage unlimited

 

 

 

 

 

 

 

 

 

 

5: Supply voltage corrected (off dur-

 

 

 

 

 

 

 

 

 

 

ing deceleration), output voltage

 

 

 

 

 

 

 

 

 

 

unlimited

 

 

 

 

11

 

0308

Braking resistor

%ED

1

1-100

3

 

6.12.4

 

 

 

operation rate

 

 

 

 

 

 

 

 

0312

Random mode

-

-

0: Disabled

0

 

6.11

 

 

 

 

 

 

 

1: Enabled

 

 

 

 

 

 

0360

PI control

-

-

0: Disabled

0

 

6.12.7

 

 

 

 

 

 

 

1: Enabled

 

 

 

 

 

 

0362

Proportional gain

-

-

0-01-100.0

0.30

 

6.12.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0363

Integral gain

-

-

0.01-100.0

0.20

 

6.12.7

 

 

 

 

 

 

 

 

 

 

 

 

 

K-5