Toshiba VF-S9 manual Jog run mode, Jog run frequency Jog run stopping pattern

Models: VF-S9

1 198
Download 198 pages 1.97 Kb
Page 103
Image 103
6.8Jog run mode

 

 

 

 

 

E6580757

 

 

 

 

 

 

 

 

[Parameter setting]

 

 

 

 

 

Title

Function

 

Adjustment range

Default setting

 

 

 

 

 

 

 

 

 

 

DC braking starting frequency

0.0

(Hz)

0.0

 

 

 

DC braking current

0.0

100 (%)

30.0

 

 

 

DC braking time

0.0

20.0 (sec)

1.0

 

Output frequency [Hz]

Set frequency

 

DC braking

DC braking starting frequency

 

 

Time [sec]

Output current [A]

DC braking current

 

DC braking time

6

 

Operation signal (F-CC)

Note: During DC braking, the overload protection sensitivity of the inverter increases. The DC braking cur- rent may be adjusted automatically to prevent tripping.

6.8Jog run mode

 : Jog run frequency : Jog run frequency

: Jog run stopping pattern

Function

Use the jog run parameters to operate the motor in jog mode. Input of a jog run signal generates a jog run frequency output at once, irrespective of the designated acceleration time.

The motor can be operated in jog mode while the jog run setting terminals are connected (RST-CC ON).(Setting Manual background to Manual background.)