■Example of call-up of trip information

E6580757

Error code

Communi-

Description

cation No.

 

 

 

 

 

(*)

0

No error

(Note) Past trip records (trip records retained or trips that occurred in the past) can be called up. (Refer to 8.1 "Status monitor mode" for the call-up procedure.)

(*)Strictly speaking, this code is not an error code; this code is displayed to show the absence of error when the past trip monitor mode is selected.

Example of call-up of trip information

 

 

Item displayed

Key

LED

Communi-

 

Description

 

 

operated

display

cation No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status monitor mode (The code blinks if a trip oc-

 

*1

 

 

 

 

curs.)

 

 

 

 

 

 

The motor coasts and comes to a stop (coast

 

 

 

 

 

 

 

 

 

 

 

 

stop).

 

 

 

Parameter setting

 

 

 

The first basic parameter "Automatic accelera-

 

 

mode

 

 

 

tion/deceleration (

)" is displayed.

 

 

Operation fre-

 

 

FE00

The operation frequency at the occurrence of a trip

 

 

quency

 

 

is displayed.

 

 

 

 

 

 

 

 

 

Direction of rota-

 

 

FE01

The direction of rotation at the occurrence of a trip

 

 

tion

 

 

is displayed. ( : forward run, : reverse run)

 

 

 

 

 

 

 

Operation fre-

 

 

FE02

The operation frequency command value at the

 

 

quency command

 

 

occurrence of a trip is displayed.

 

 

 

 

 

 

 

Load current

 

 

FE03

The inverter output current at the occurrence of a

 

 

 

 

trip is displayed. (Default setting: unit %)

 

 

 

 

 

 

 

 

Input (DC) voltage

 

 

FE04

The inverter input (DC) voltage at the occurrence

 

 

 

 

of a trip is displayed. (Default setting: unit %)

 

 

 

 

 

 

8

 

 

 

 

 

 

 

Output voltage

 

 

FE05

The inverter output voltage at the occurrence of a

 

 

 

trip is displayed. (Default setting: unit %)

 

 

 

 

 

 

 

 

 

 

 

The ON/OFF status of each of the control signal

 

 

 

 

 

 

 

 

 

 

 

 

input terminals (F, R, RST, S1, S2 and S3) at the

 

 

 

 

 

 

occurrence of a trip is displayed in bits.

 

 

Input terminal

 

 

FE06

ON:

 

 

 

 

 

OFF:

Input terminal (F)

 

 

 

 

 

 

Input terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

(S3)

Input terminal (R)

 

 

 

 

 

 

Input terminal

Input terminal (RST)

 

 

 

 

 

 

(S2)

Input terminal (S1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The ON/OFF status of each of the control signal

 

 

 

 

 

 

output terminals (RY, OUT and FL) at the occur-

 

 

 

 

 

 

rence of a trip is displayed in bits.

 

 

Output terminal

 

 

FE07

ON:

 

 

 

 

 

 

 

OFF:

Output terminal

 

 

 

 

 

 

Output terminal (FL)

 

 

 

 

 

 

(RY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output terminal (OUT)

 

 

CPU version

 

 

FE08

The version of the CPU is displayed.

 

 

 

 

 

 

 

 

 

 

(Continued overleaf)

 

 

 

 

 