Installation
32 Instruction manual SGE
3is
The following example illustrates how to use the table.
Practical example of concentric chimney flue
Example
The figure shows a SGE 60 installation. The appliance must be fitted with 10 m
of concentric pipe (C13/C33) and four 90 degree bends. The configuration must
be checked for compliance with the requirements stated in the table.
Appliance with concentric flue gas discharge material
According to the table, the maximum length allowed is 15 metres, and there may
be up to three 90 degree bends 4. Both requirements are fulfilled.
Specifications
Caution
For type C13 and C33 installations,A.O. Smith prescribes the use of a roof
or wall-mounted terminal, exclusively of a type approved for the appliance. Use
of an incorrect roof or wall-mounted flue terminal can cause the installation to
malfunction.