12 Service program
12.1 Introduction
The service program is used by the installation engineer or service and maintenance engineer for:
•Setting the hysteresis
•Displaying the error history
•Displaying the appliance history
•Display the selected appliance
•Setting the service interval
•Setting legionella prevention
•Solar heating system configuration
•Setting the central heating configuration
SERVICE MENU
»HYSTERESE
^HISTORY OF ERRORS È APPLIANCE HISTORY
SELECT APPLIANCE
SERVICE INTERVAL
ANTI LEGIONELLA
SETTINGS SOLAR
SETTINGS HEATING
These
Note
The notation convention for the service menu is identical to that of the main menu (11.2 "Notational convention for
difference is, you use to bring up the service program, instead of which brings up the main menu.
12.2 Setting the hysteresis
Call up the menu to set the hysteresis as follows:
: HYSTERESE DOWN
HYSTERESE DOWN »3ÉC
Appliance | Default | Range |
|
|
|
40 | - °C. | - °C. |
|
|
|
60 | 5 °C. | 2 ... 7 °C. |
|
|
|
12.3Displaying the error history
Display the error history as follows:
• : HISTORY OF ERRORS
The controller will display an overview of "Blocking errors" and "Lock out errors". In both cases, the electronic controller reserves 15 lines for the last 15 error messages. If there are fewer than 15 error messages, an ellipsis (...) is displayed. The display
first shows the "Blocking errors". When is pressed, the "Lock out errors" are then displayed.
The figure shows an example of "Blocking errors". In this case, the text HISTORY OF ERRORS is followed by (B).
HISTORY OF ERRORS(B)
S04 SENSOR ERROR
F06 IONIZATION
È CO2 50 HZ ERROR
The figure shows an example of "Lock out errors". In this case, the text HISTORY OF ERRORS is followed by (L).
HISTORY OF ERRORS(L) F02 FAN
F07 FLAME ERROR È ...
Note
For an overview of all errors and the possible causes, please refer to the relevant
chapter (13 "Troubleshooting").
12.4 Displaying the appliance history
The appliance history submenu is used to display the burning hours, the number of ignitions, the number of flame errors and the number of ignition errors.
Call up the menu for displaying the appliance history as follows:
•: APPLIANCE HISTORY
The figure shows an example.
Instruction manual SGE | 73 |