Service program

76 Instruction manual SGE

12 is
•:
SETTINGS SOLAR
|
SOLAR DIFFERENCE

12.9.6 Setting the QT sensor yes/no

The energy contribution of the solar heating system
can be calculated (12.9.7 "Reading the energy
contribution of the solar heating system") with the aid
of the Q/T sensor. This calculation is only possible if
your installation is equipped with such a Q/T sensor. If
this is the case, then you must set this value to
YES
,
otherwise
NO
. Call up the applicable menu as follows:
•:
SETTINGS SOLAR
|
QT SENSOR

12.9.7 Reading the energy contribution of

the solar heating system

This option enables you to read out how much energy
the solar heating system supplies. For this data to be
displayed, the installation must be equipped with a QT
sensor (12.9.6 "Setting the QT sensor yes/no").
3 values are reported on the display:
ACTUAL
, actual energy: the amount of energy
currently being supplied.
LAST 24hr
, energy supplied over last 24 hours.
TOTAL
, total energy supplied since day 1.
Call up this menu as follows:
•:
SETTINGS SOLAR
|
CONTRIBUTION

12.10 Setting the central heating

configuration

Use this menu to specify whether a central heating
system is connected to the installation.
Note
This function is not yet available.
•:
SETTINGS HEATING
SOLAR DIFFERENCE
5ÉC
Appliance Default Range
40 - °C. - °C.
60 0 ... 8°C. 5 °C.
QT SENSOR
YES
»NO
CONTRIBUTION
ACTUAL 00000 kW
LAST 24hr 00000 kJ
TOTAL 00000 Mj
SETTINGS HEATING