is
3.13Checking the supply pressure and burner pressure
Legend
Only applicable numbers are mentioned.
1.supply pressure test nipple
2.burner pressure test nipple
3.burner pressure regulator
4.burner pressure control cap
5.burner pressure control adjusting screw
3.Connect earth to
4.Connect the "flow signal" to
5.Fit the cable in the strain relief.
6.If you have no more connections to make:
-Fit the cap on the electrical terminal block.
-Fit the plastic covers onto the appliance.
Note
Before starting the appliance and/or checking the supply pressure and burner pressure, you must fill (5 "Filling") the appliance.
Caution
Before starting up for the first time or after conversion, you must always check the supply pressure and burner pressure.
Note
The easiest way to check the gas pressures is by using two pressure gauges. This procedure assumes that these two gauges are available.
Gas control
1
2
4
3
5 | |
|
Instruction manual SGE | 41 |