| is | |
13.4 Displayed warnings |
|
|
|
| |
Displayed warnings |
|
|
|
|
|
|
|
|
|
| |
Symptom | Cause | Solution | Remark |
| |
|
|
|
|
|
|
Q/T sensor not | Lead(s) loosened or | Appliance runs, but displays a warning | 1. | Properly connect Q/T sensor and the warning will disappear |
|
correctly connected | incorrectly connected |
| 2. | If correctly wired but the warning remains, replace sensor |
|
|
|
|
| ||
|
|
| Note: To have the sensor connected or replaced, contact your |
| |
|
|
| installation engineer |
| |
Collector temperature | Temperature S1 is | The pump in the solar circuit switches off, until S1 < 70°C | 1. | You can let the message disappear automatically by allowing |
|
excessive | higher than Tcollector |
|
| the heating fluid to cool down |
|
| max |
| 2. | You can also manually eliminate the message by pressing the |
|
|
|
|
| RESET and ENTER button simultaneously |
|
|
|
|
|
| |
Maximum burning | The actual burning | Appliance runs, but displays a warning | For maintenance to your appliance, contact your installation |
| |
hours: Service required | hours have exceeded |
| engineer |
| |
| the preset burning |
|
|
|
|
| hours |
|
|
|
|
Instruction manual SGE | 90 |