is
Dimensions (all dimensions in mm, unless otherwise stated)
Dime | Description | SGE 40 | SGE 60 |
nsion |
|
|
|
|
|
|
|
A | Total height |
| 2055 |
|
|
|
|
C | Position on pallet |
| 490 |
|
|
|
|
D | Appliance diameter |
| 705 |
|
|
|
|
E | Depth |
| 925 |
|
|
|
|
F | Width |
| 755 |
|
|
|
|
G | Diameter of chimney flue |
| 100 / 150 |
|
|
|
|
H | Height of chimney flue |
| 1995 |
|
|
|
|
Hx | x position of chimney flue outlet |
| 260 |
|
|
|
|
Hy | y position of chimney flue outlet |
| 370 |
|
|
|
|
K | Height of gas/burner connection |
| 1945 |
|
|
|
|
M | Height of cold water supply |
| 185 |
|
|
|
|
N | Height of hot water outlet |
| 2055 |
|
|
|
|
Ny | y position of hot water outlet |
| 205 |
|
|
|
|
P | Height of cleaning opening |
| 365 |
|
|
|
|
R | Height of drain valve connection |
| 180 |
|
|
|
|
S | Height of T&P valve connection |
| 1485 |
|
|
|
|
T | Height of coil inlet |
| 630 |
|
|
|
|
U | Height of coil outlet |
| 305 |
|
|
|
|
V | Height of recirculation connection |
| 1035 |
|
|
|
|
W | Height of condensation drain |
| 765 |
|
|
|
|
X | Height of heat exchanger supply |
| 1465 |
|
|
|
|
Y | Height of heat exchanger discharge |
| 855 |
|
|
|
|
Z | Height of electric element connection |
| 755 |
|
|
|
|
1 | Cold water supply connection (male) |
| R 11/2 |
2 | Hot water outlet (male) |
| R 11/ |
|
|
| 2 |
3 | Gas control connection (female) |
| R 3/4 |
4 | Drain valve connection (female) |
| 3/ " |
|
|
| 4 |
5 | T&P valve connection (female) |
| 1 - 11.5 NPT |
|
|
|
|
6 | Cleaning/inspection opening |
| 95 x 70 |
|
|
|
|
7 | Condensation drainage connection (female) |
| Rp 1 |
|
|
|
|
9 | Coil inlet connection (female) |
| Rp 1 |
|
|
|
|
10 | Coil outlet connection (female) |
| Rp 1 |
|
|
|
|
11 | Electric element connection (female) |
| R 11/ |
|
|
| 2 |
12 | Heat exchanger supply conn. (female) |
| Rp 1 |
|
|
|
|
13 | Heat exchanger discharge conn. (female) |
| Rp 1 |
|
|
|
|
14 | Recirculation connection (female) |
| Rp 1 |
|
|
|
|
Instruction manual SGE | 23 |