is
14Maintenance frequency
14.1 Introduction | A service should be carried out at least once a year, both on the water side and |
| on the gas side. Maintenance frequency depends, among other things, on the |
| water quality, the average burning time per day and the set water temperature. |
|
|
| Note |
| Regular maintenance extends the service life of the appliance. |
| To determine the correct maintenance frequency, it is recommended to arrange |
| for the service and maintenance engineer to check the appliance on both the |
| water and gas side, three months after installation. Based on this check, the |
| best maintenance frequency can be determined. |
|
|
14.2Determining service To aid servicing, the electronic controller has a service interval with which the
interval | service and maintenance engineer can determine the frequency of |
| maintenance, based on the number of burning hours. |
| The service interval can be set to: 500, 1000 or 1500 burning hours. The |
| standard setting is 500 burning hours. |
|
|
| Example |
| In the first three months, the appliance has burnt 300 hours. During |
| maintenance, it is evident that one service per year will be sufficient. Therefore, |
| after one year, some 1200 burning hours will have elapsed. The first value below |
| 1200 hours that can be selected is 1000 burning hours. |
| In this case, the service and maintenance engineer sets the interval to 1000. |
| In the first three months, the appliance has burned for 300 hours. During |
| maintenance, it is evident (perhaps due to the water quality) that service will be |
| required at least once every 6 months. |
| Therefore, after six months, some 600 burning hours will have elapsed. The first |
| value below 600 hours that can be selected is 500 burning hours. |
| In this case, the service and maintenance engineer sets the interval to 500. |
|
|
!!! WARNING !!!
MAX. BURNINGHOURS:
SERVICE REQUIRED
Once the set number of burning hours has elapsed, the message SERVICE REQUIRED will appear on the display. When this message appears, the service and maintenance engineer must be contacted.
Instruction manual SGE | 91 |