3.3.1 Air humidity and ambient temperature
The boiler room must be frost-free, or be protected against frost. The table
shows the environmental conditions that must be adhered to for correct
functioning of the electronics present in the appliance to be guaranteed.
Air humidity and ambient temperature specifications
3.3.2 Appliance maximum floor load
In connection with the appliance's weight, take account of the maximum floor
loading, refer to the table.
Weight specifications related to maximum floor load
3.3.3 Water composition
The appliance is intended for heating drinking water. The drinking water must
comply with the regulations governing drinking water for human consumption.
The table gives an overview of the specifications.
Water specifications
Note
If the water specifications deviate from those stated in the table, then the
tank protection cannot be guaranteed(16 "Warranty (certificate)").
Air humidity and ambient temperature
Air humidity max. 93% RV at +25°C
Ambient temperature Functional: 0 < T < 60°C
Weight (kg) of the appliance filled with water
SGE 40 and 60 615
Water comp osition
Hardness
(alkaline earth ions)
> 1.00 mmol/l:
German hardness> 5.6° dH
French hardness > 10.0° fH
English hardness > 7.0° eH
Conductivity > 125 µS/cm