Instruction manual SGE 59

gis
8 Status of the appliance

8.1 Introduction

Topics covered in this chapter:
Operating modes;
Error conditions;
Service condition.

8.2 Operating modes

When running, the appliance has four basic operating
modes, namely:
OFF
ON
EXTRA
PROG

8.2.1

OFF
In this mode, the frost protection is activated. The
figure shows the display with the following information:
line one: the text
OFF
;
line two: the time, the day and alternately (9.3 "The
appliance's heating cycle") T1 and Tnet.
lines three and four: the text
FROST PROTECTION ACTIVATED
.

8.2.2

ON
In this mode, the appliance continually responds to the
hot water demand. The figure shows the display with
the following information:
line one: the text
ON
;
line two: the time, the day and alternately (9.3 "The
appliance's heating cycle") T1 and Tnet.
line three: the programmed water temperature T
set
;
line four: blank when the appliance is idle, or
depending on the heating cycle (9.3 "The
appliance's heating cycle"), displays a text such as
HEAT DEMAND
.

8.2.3

EXTRA
In this mode, one extra period is programmed and
activated. In this mode, the
OFF
or
PROG
mode is
temporarily overruled to fulfil a single period of
demand. Once the period has passed, the appliance
automatically returns to the previous operating mode.
The figure shows the display with the following
information:
line one: the text
EXTRA
;
line two: the time, the day and alternately (9.3 "The
appliance's heating cycle") T1 and Tnet;
line three: the switch-on time, and the related
water temperature setting;
line four: the text
PERIOD ACTIVATED
.

8.2.4

PROG
In this mode a preset week program is active, and the
appliance responds continually to demand within the
time periods set in the week program. There are two
distinct situations possible in this mode:
1. The current time falls within a set time period
of the week program.
The figure shows the display with the following
information:
- line one: the text
PROG
;
- line two: the time, the day and T1 and Tnet
alternately (9.3 "The appliance's heating
cycle");
- line three: the next scheduled switch-off time
and the water temperature Tset of the active
period;
OFF
13:45 Thursday 6ÉC
FROST PROTECTION
ACTIVATED
ON
13:45 Thursday 67ÉC
Tset 75ÉC
EXTRA
12:30 Thursday 76ÉC
TH 12:45 Tset 75ÉC
PERIOD ACTIVATED
PROG
10:00 Monday 76ÉC
MO 11:15 Tset 75ÉC