E6580757

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

 

 

Device

 

 

 

 

 

Function and purpose

 

 

 

 

 

 

(11)

 

Parameter writer

 

Use this unit for batch read, batch copy, and batch writing of setting parameters.

 

 

 

 

 

 

 

 

(Model: PWU001Z)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extension panel

 

Extended operation panel kit provided with LED indication section, RUN/STOP key,

 

 

 

(12)

 

 

 

 

 

UP/DOWN key, Monitor key, and Enter key.

 

 

 

 

 

 

 

 

 

 

 

 

 

(Model: RKP001Z)

 

 

 

 

 

 

 

 

 

 

(13)

 

RS485 communication

 

Use to connect a personal computer for data communication with up to 64 units.

 

 

 

 

converter unit

 

(Model: RS4001Z)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(14)

 

RS232C communication

 

Use to connect a personal computer for data communication.

 

 

 

 

 

 

converter unit

 

(Model: RS2001Z)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote panel

 

Provided with built-in frequency indicator, frequency setting device, and RUN-STOP (for-

 

 

(10)

 

 

 

 

 

ward/reverse) switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Model: CBVR-7B1)

 

 

 

 

 

 

 

 

 

 

(15)

 

Application control unit

 

AP Series is available to enable various types of application control functions when com-

 

 

 

 

 

 

 

bined with an inverter. Contact your Toshiba representative for further information.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table for selection of optional external devices

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Radio noise

 

 

 

Motor-end

 

 

 

 

 

 

Voltage

 

Capacity of

 

 

Input AC

DC

reduction filter

 

 

Braking

Conduit

Foot-mounted type

 

DIN

 

 

 

 

 

 

 

surge voltage

 

 

 

 

applicable

Inverter model

 

reactor

reactor

High-

 

 

 

 

 

class

 

 

Core type

 

resistor

suppression

pipe kit

noise reduction filter

 

adapter

 

 

 

motor

 

 

(Note 2)

(Note 2)

attenuation

 

 

 

 

 

 

 

 

(See Note 1.)

 

filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-

 

0.2

VFS9S-2002PL

 

PFL-2002S

DCLS-2002

-

RC5078

 

PBR-2007

-

NEM010Z

EMFS2010AZ

 

DIN001Z

 

 

 

0.4

VFS9S-2004PL

 

PFL-2005S

DCL-2007

-

RC5078

 

PBR-2007

-

NEM010Z

EMFS2010AZ

 

DIN001Z

 

 

phase

 

 

 

 

 

 

200V

 

0.75

VFS9S-2007PL

 

PFL-2011S

DCL-2022

-

RC5078

 

PBR-2007

-

NEM010Z

EMFS2010AZ

 

DIN001Z

 

 

 

1.5

VFS9S-2015PL

 

PFL-2018S

DCL-2037

-

RC5078

 

PBR-2022

-

NEM020Z

EMFS2016CZ

 

-

 

 

class

 

 

 

 

 

 

 

2.2

VFS9S-2022PL

 

PFL-2018S

DCL-2037

-

RC5078

 

PBR-2022

-

NEM030Z

EMFS2025DZ

 

-

 

 

 

 

 

 

 

 

 

 

 

0.2

VFS9-2002PM

 

PFL-2001S

DCL-2002

NF3005A-MJ

RC5078

 

PBR-2007

 

NEM011Z

EMF2011BZ

 

DIN001Z

 

 

 

 

0.4

VFS9-2004PM

 

PFL-2005S

DCL-2007

NF3005A-MJ

RC5078

 

PBR-2007

-

NEM011Z

EMF2011BZ

 

DIN001Z

 

 

 

 

0.75

VFS9-2007PM

 

PFL-2005S

DCL-2007

NF3005A-MJ

RC5078

 

PBR-2007

-

NEM011Z

EMF2011BZ

 

DIN001Z

 

 

Three-

 

1.5

VFS9-2015PM

 

PFL-2011S

DCL-2022

NF3015A-MJ

RC5078

 

PBR-2022

-

NEM011Z

EMF2011BZ

 

-

 

 

phase

 

2.2

VFS9-2022PM

 

PFL-2011S

DCL-2022

NF3015A-MJ

RC5078

 

PBR-2022

-

NEM031Z

EMF4022DZ

 

-

 

 

200V

 

3.7

VFS9-2037PM

 

PFL-2018S

DCL-2037

NF3020A-MJ

RC5078

 

PBR-2037

-

NEM031Z

EMF4022DZ

 

-

 

 

class

 

5.5

VFS9-2055PL

 

PFL-2025S

DCL-2055

-

RC9129

 

PB3-2055

-

NEM040Z

EMF4045EZ

 

-

 

 

 

 

7.5

VFS9-2075PL

 

PFL-2050S

DCL-2110

-

RC9129

 

PBR-2075

-

NEM040Z

EMF4045EZ

 

-

 

 

 

 

11

VFS9-2110PM

 

PFL-2050S

DCL-2110

NF3050A-MJ

RC9129

 

PBR-2110

-

NEM050Z

EMF2080GZ

 

 

 

 

 

 

15

VFS9-2150PM

 

PFL-2100S

DCL-2220

NF3080A-MJ

RC9129

 

PBR-2150

-

NEM050Z

EMF2080GZ

 

-

 

 

 

 

0.75

VFS9-4007PL

 

PFL-4012S

DCL-2007

-

RC5078

 

PBR-2007

MSF-4015Z

NEM020Z

EMF4006CZ

 

-

 

 

Three-

 

1.5

VFS9-4015PL

 

PFL-4012S

DCL-2007

-

RC5078

 

PBR-2007

MSF-4015Z

NEM020Z

EMF4006CZ

 

-

 

 

 

2.2

VFS9-4022PL

 

PFL-4012S

DCL-2022

-

RC5078

 

PBR-2007

MSF-4037Z

NEM030Z

EMF4022DZ

 

-

 

 

phase

 

 

 

 

 

 

 

3.7

VFS9-4037PL

 

PFL-4012S

DCL-2022

-

RC5078

 

PBR-2007

MSF-4037Z

NEM030Z

EMF4022DZ

 

-

 

 

400V

 

 

 

 

 

 

 

5.5

VFS9-4055PL

 

PFL-4025S

DCL-4110

-

RC9129

 

PBR3-4055

MSF-4075Z

NEM040Z

EMF4045EZ

 

-

 

10

class

 

 

 

 

 

 

7.5

VFS9-4075PL

 

PFL-4025S

DCL-4110

-

RC9129

 

PBR3-4075

MSF-4075Z

NEM040Z

EMF4045EZ

 

-

 

 

 

 

 

 

 

 

 

11

VFS9-4110PL

 

PFL-4025S

DCL-4110

-

RC9129

 

PBR3-4110

MSF-4150Z

NEM050Z

EMF4045FZ

 

-

 

 

 

 

15

VFS9-4150PL

 

PFL-4050S

DCL-4220

-

RC9129

 

PBR3-4150

MSF-4150Z

NEM050Z

EMF4045FZ

 

-

 

Note 1: This filter is used wound around the input-side power line. (Number of turns: 4 or more) This filter can be installed on the output side, as well.

Note 2: Connecting this reactor to the inverter makes it compliant with the standard "General Inverter (input current of 20A or less) Harmonic Suppression Measures Execution Guidelines" set by the Japan Elec- tric Industry Association.

J-6

Page 162
Image 162
Toshiba VF-S9 manual Parameter writer, Model PWU001Z Extension panel, UP/DOWN key, Monitor key, and Enter key Model RKP001Z