| E6580757 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No. |
|
| Device |
|
|
|
|
| Function and purpose |
|
|
|
|
| |||
| (11) |
| Parameter writer |
| Use this unit for batch read, batch copy, and batch writing of setting parameters. |
|
| |||||||||||
|
|
|
|
|
| (Model: PWU001Z) |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| Extension panel |
| Extended operation panel kit provided with LED indication section, RUN/STOP key, |
|
| |||||||||||
| (12) |
|
|
|
|
| UP/DOWN key, Monitor key, and Enter key. |
|
|
|
|
|
| |||||
|
|
|
|
|
|
| (Model: RKP001Z) |
|
|
|
|
|
|
|
|
| ||
| (13) |
| RS485 communication |
| Use to connect a personal computer for data communication with up to 64 units. |
|
| |||||||||||
|
| converter unit |
| (Model: RS4001Z) |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| (14) |
| RS232C communication |
| Use to connect a personal computer for data communication. |
|
|
|
| |||||||||
|
| converter unit |
| (Model: RS2001Z) |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| Remote panel |
| Provided with |
| ||||||||||||
| (10) |
|
|
|
|
| ward/reverse) switch. |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| (Model: |
|
|
|
|
|
|
|
|
| ||
| (15) |
| Application control unit |
| AP Series is available to enable various types of application control functions when com- |
| ||||||||||||
|
|
|
|
|
| bined with an inverter. Contact your Toshiba representative for further information. |
|
| ||||||||||
|
|
|
|
|
|
|
|
| ||||||||||
|
|
| Table for selection of optional external devices |
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| Radio noise |
|
|
|
|
|
|
|
| |
| Voltage |
| Capacity of |
|
| Input AC | DC | reduction filter |
|
| Braking | Conduit |
| DIN |
| |||
|
|
|
|
|
| surge voltage |
|
| ||||||||||
|
| applicable | Inverter model |
| reactor | reactor | High- |
|
|
|
| |||||||
| class |
|
| Core type |
| resistor | suppression | pipe kit | noise reduction filter |
| adapter |
| ||||||
|
| motor |
|
| (Note 2) | (Note 2) | attenuation |
|
|
| ||||||||
|
|
|
|
| (See Note 1.) |
| filter |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| type |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Single- |
| 0.2 |
| - | RC5078 |
| - | NEM010Z | EMFS2010AZ |
| DIN001Z |
| |||||
|
| 0.4 |
| - | RC5078 |
| - | NEM010Z | EMFS2010AZ |
| DIN001Z |
| ||||||
| phase |
|
|
|
|
| ||||||||||||
| 200V |
| 0.75 |
| - | RC5078 |
| - | NEM010Z | EMFS2010AZ |
| DIN001Z |
| |||||
|
| 1.5 |
| - | RC5078 |
| - | NEM020Z | EMFS2016CZ |
| - |
| ||||||
| class |
|
|
|
|
| ||||||||||||
|
| 2.2 |
| - | RC5078 |
| - | NEM030Z | EMFS2025DZ |
| - |
| ||||||
|
|
|
|
|
|
| ||||||||||||
|
|
| 0.2 |
| RC5078 |
|
| NEM011Z | EMF2011BZ |
| DIN001Z |
| ||||||
|
|
| 0.4 |
| RC5078 |
| - | NEM011Z | EMF2011BZ |
| DIN001Z |
| ||||||
|
|
| 0.75 |
| RC5078 |
| - | NEM011Z | EMF2011BZ |
| DIN001Z |
| ||||||
| Three- |
| 1.5 |
| RC5078 |
| - | NEM011Z | EMF2011BZ |
| - |
| ||||||
| phase |
| 2.2 |
| RC5078 |
| - | NEM031Z | EMF4022DZ |
| - |
| ||||||
| 200V |
| 3.7 |
| RC5078 |
| - | NEM031Z | EMF4022DZ |
| - |
| ||||||
| class |
| 5.5 |
| - | RC9129 |
| - | NEM040Z | EMF4045EZ |
| - |
| |||||
|
|
| 7.5 |
| - | RC9129 |
| - | NEM040Z | EMF4045EZ |
| - |
| |||||
|
|
| 11 |
| RC9129 |
| - | NEM050Z | EMF2080GZ |
|
|
| ||||||
|
|
| 15 |
| RC9129 |
| - | NEM050Z | EMF2080GZ |
| - |
| ||||||
|
|
| 0.75 |
| - | RC5078 |
| NEM020Z | EMF4006CZ |
| - |
| ||||||
| Three- |
| 1.5 |
| - | RC5078 |
| NEM020Z | EMF4006CZ |
| - |
| ||||||
|
| 2.2 |
| - | RC5078 |
| NEM030Z | EMF4022DZ |
| - |
| |||||||
| phase |
|
|
|
|
| ||||||||||||
|
| 3.7 |
| - | RC5078 |
| NEM030Z | EMF4022DZ |
| - |
| |||||||
| 400V |
|
|
|
|
| ||||||||||||
|
| 5.5 |
| - | RC9129 |
| NEM040Z | EMF4045EZ |
| - |
| |||||||
10 | class |
|
|
|
|
| ||||||||||||
| 7.5 |
| - | RC9129 |
| NEM040Z | EMF4045EZ |
| - |
| ||||||||
|
|
|
|
|
| |||||||||||||
|
| 11 |
| - | RC9129 |
| NEM050Z | EMF4045FZ |
| - |
| |||||||
|
|
| 15 |
| - | RC9129 |
| NEM050Z | EMF4045FZ |
| - |
|
Note 1: This filter is used wound around the
Note 2: Connecting this reactor to the inverter makes it compliant with the standard "General Inverter (input current of 20A or less) Harmonic Suppression Measures Execution Guidelines" set by the Japan Elec- tric Industry Association.