Toshiba VF-S9 manual Table of input terminal functions 2/3

Models: VF-S9

1 198
Download 198 pages 1.97 Kb
Page 176
Image 176
■Table of input terminal functions (2/3)

E6580757

Table of input terminal functions (2/3)

Function

Code

Function

 

 

 

Action

 

 

 

 

 

No.

 

 

 

 

 

 

 

 

 

 

 

16

ST+RST

Combination of standby and reset commands

ON: Simultaneous input from ST and RST

 

 

 

17

ST+PNL/TB

Combination of standby and operation

ON: Simultaneous input from ST and PNL/TB

 

 

 

 

 

panel/terminal board switching

 

 

 

 

 

 

 

 

 

18

F+JOG

Combination of forward run and jog run

ON: Simultaneous input from F and JOG

 

 

 

19

R+JOG

Combination of reverse run and jog run

ON: Simultaneous input from R and JOG

 

 

 

20

F+AD2

Combination of forward run and acceleration/

ON: Simultaneous input from F and AD2

 

 

 

 

 

deceleration 2

 

 

 

 

 

 

 

 

 

21

R+AD2

Combination of reverse run and acceleration/

ON: Simultaneous input from R and AD2

 

 

 

 

 

deceleration 2

 

 

 

 

 

 

 

 

 

22

F+SS1

Combination of forward run and preset-speed

ON: Simultaneous input from F and SS1

 

 

 

 

 

command 1

 

 

 

 

 

 

 

 

 

23

R+SS1

Combination of reverse run and preset-speed

ON: Simultaneous input from R and SS1

 

 

 

 

 

command 1

 

 

 

 

 

 

 

 

 

24

F+SS2

Combination of forward run and preset-speed

ON: Simultaneous input from F and SS2

 

 

 

 

 

command 2

 

 

 

 

 

 

 

 

 

25

R+SS2

Combination of reverse run and preset-speed

ON: Simultaneous input from R and SS2

 

 

 

 

 

command 2

 

 

 

 

 

 

 

 

 

26

F+SS3

Combination of forward run and preset-speed

ON: Simultaneous input from F and SS3

 

 

 

 

 

command 3

 

 

 

 

 

 

 

 

 

27

R+SS3

Combination of reverse run and preset-speed

ON: Simultaneous input from R and SS3

 

 

 

 

 

command 3

 

 

 

 

 

 

 

 

 

28

F+SS4

Combination of forward run and preset-speed

ON: Simultaneous input from F and SS4

 

 

 

 

 

command 4

 

 

 

 

 

 

 

 

 

29

R+SS4

Combination of reverse run and preset-speed

ON: Simultaneous input from R and SS4

 

 

 

 

 

command 4

 

 

 

 

 

 

 

 

 

30

F+SS1+AD2

Combination of forward run, preset-speed

ON: Simultaneous input from F, SS1 and AD2

 

 

 

 

 

command 1 and acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

31

R+SS1+AD2

Combination of reverse run, preset-speed

ON: Simultaneous input from R, SS1 and AD2

 

 

 

 

 

command 1 and acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

32

F+SS2+AD2

Combination of forward run, preset-speed

ON: Simultaneous input from F, SS2 and AD2

 

 

 

 

 

command 2 and acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

33

R+SS2+AD2

Combination of reverse run, preset-speed

ON: Simultaneous input from R, SS2 and AD2

 

 

 

 

 

command 2 and acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

34

F+SS3+AD2

Combination of forward run, preset-speed

ON: Simultaneous input from F, SS3 and AD2

 

 

 

 

 

command 3 and acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

35

R+SS3+AD2

Combination of reverse run, preset-speed

ON: Simultaneous input from R, SS3 and AD2

 

 

 

 

 

command 3 and acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

36

F+SS4+AD2

Combination of forward run, preset-speed

ON: Simultaneous input from F, SS4 and AD2

 

 

 

 

 

command 4 and acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

37

R+SS4+AD2

Combination of reverse run, preset-speed

ON: Simultaneous input from R, SS4 and AD2

 

 

 

 

 

command 4 and acceleration/deceleration 2

 

 

 

 

 

 

 

 

 

38

FCHG

Frequency command forced switching

Enabled if

: 2

 

 

 

 

 

 

 

 

 

ON: VIB

 

 

 

 

 

 

 

11

 

 

 

OFF: VIA/II

 

 

 

 

 

 

39

THR2

No. 2 thermal switching

ON: No. 2 thermal

 

 

 

 

 

 

 

 

 

(....

: 0,

,

 

,

)

 

 

 

 

 

 

OFF: No. 1 thermal

 

 

 

 

 

 

 

 

 

(

setting: ,

, )

 

 

 

 

40

MCHG

No. 2 motor switching

ON: No. 2 motor

 

 

 

 

 

 

 

 

 

 

(....

: 0,

,

 

,

,

,

 

 

 

 

 

 

,

)

 

 

 

 

 

 

 

 

 

OFF: No. 1 motor

 

 

 

 

 

 

 

 

 

 

(

setting: ,

,

,

,

,

 

 

 

 

 

 

)

 

 

 

 

 

 

 

41

UP

Frequency UP signal input from external contacts

Enabled if

 

 

 

 

 

 

 

 

 

 

ON: Increase in frequency

 

 

 

 

 

42

DOWN

Frequency DOWN signal input from external

Enabled if

 

 

 

 

 

 

 

 

 

contacts

ON: Decrease in frequency

 

 

 

 

 

43

CLR

Frequency UP/DOWN clear signal input from

OffON: Resetting of UP/DOWN frequency by

 

 

 

 

 

external contacts

 

means of external contacts

 

 

 

 

44

CLR+RST

Combination of frequency UP/DOWN clear and

ON: Simultaneous input from CLR and RST

 

 

 

 

 

reset by means of external contacts

 

 

 

 

 

 

 

 

 

K-9