PRODUCT FEATURES | BBV, SBV Series Natural Vent Gas Fireplaces |
PRODUCT SPECIFICATIONS
•This appliance has been certified for use with either natural or propane gas. See appropriate data plates.
•This appliance is not for use with solid fuels.
•The appliance must be installed in accordance with local codes if any. If none exist use the current instal- lation code, ANSI Z223.1/NFPA 54 in the US and CSA B149 in Canada.
•The appliance must be properly connected to a vent- ing system.
•The appliance is not approved for closet or recessed installations.
GAS pressures
| Natural | Propane (LP) |
Inlet Minimum | 4.5” w.c. | 11.0” w.c. |
Inlet Maximum | 10.5” w.c. | 13.0” w.c. |
Manifold Pressure | 3.5” w.c. | 10.0” w.c. |
Gas Specifications & ORIFICE SIZE
|
| Max.Input | Min. Input | Orifice |
Model | Fuel | BTU/h | BTU/h | Size |
BBV400NV | Nat. | 22,000 | 16,000 | #43 |
BBV400PV | LP | 22,000 | 14,500 | #55 |
SBV400NV | Nat. | 29,000 | 16,500 | #41 |
SBV400PV | LP | 29,000 | 16,300 | #53 |
SBV500NV | Nat. | 31,500 | 19,000 | #37 |
SBV500PV | LP | 31,500 | 20,000 | #52 |
FP1920
Gas Control (not shown)
Figure 1 - BBV/SBV Fireplace
1/2” Nailing Flange
5/8”
Nailing
Flanges
1/2”
Nailing
Flange
BEFORE YOU START
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any dam- age is found. Do not install any unit with damaged, incom- plete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following:
•Fireplace (Firebox and Burner System)
• | Log Set | • | Volcanic Rock |
• | Rock Wool | • | White Toggle Switch |
• | Switch Cover Plate | • | Plastic Bag (1) |
•Ziplock Bag 2” x 3” x 3”
ITEMS REQUIRED FOR INSTALLATION
• Phillips Screwdriver | • Framing Materials |
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are cer- tified without deration for elevations up to 4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, in- stallation must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdic- tion.
In Canada, please consult provincial and/or local au- thorities having jurisdiciton for installation at elevations above 4,500 feet (1,370 m).
• | Hammer | • | Wall Finishing Materials |
• Saw and/or saber saw | • | Level | |
• Electric Drill and Bits | • | Tee Joint | |
• | Pliers | • | Measuring Tape |
• | Square | • | Pipe Wrench |
•Caulking Material (Noncombustible)
•Fireplace Surround Material (Noncombustible)
•Piping Complying with Local Codes
•Pipe Sealant Approved for use with Propane/LPG (Resistant to Sulfur Compounds)