Monessen Hearth SBV400 Lighting Pilot, Operating Instructions, Approved Leak Testing Method, body

Models: SBV400 BBV400 SBV500

1 40
Download 40 pages 17 b
Page 21
Image 21
OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

BBV, SBV Series Natural Vent Gas Fireplaces

APPROVED LEAK TESTING METHOD LIGHTING PILOT FOR THE FIRST TIME Never check for gas leaks with openflame!

APPROVED LEAK TESTING METHOD

You may check for gas leaks with the following methods only:

Soap and water solution

An approved leak testing spray

Electronic sniffer

 

DANGER

Never check for gas leaks with open

 

 

 

 

flame!

 

 

 

 

WARNING

If using a soap and water solu-

 

 

 

 

tion to test for leaks, DO NOT

 

 

spray solution onto control

 

 

body.

 

 

 

NOTE: Remove any excessive pipe compound from the connec- tions. Excessive pipe compound can set off electronic sniffers.

Check for gas leaks in each of the following locations: Pipe from the gas supply line connection to the gas valve

Burner connections

Field made joints / gas shut-off valve

Pilot

Factory made joints

Each joint or connection

All joints on valve and control body

WARNING

LIGHTING PILOT If using a soap and water solu-

The control has an interlock device that does not allow the lighting of the fireplace up to the moment the safety device of the flame has not interrupted the gas flow. After that pe- riod of time (when the magnet is closed), it is possible to start the lighting operation.

The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.

1.Depress and turn knob counterclockwise tion to test for leaks, DO NOT to pilot position.

2.Depress fully and hold pilot gas knob. The electronic ig- nitor will automatically ignite the pilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.

If the pilot does not stay lit, repeat Steps 1 and 2.

 

O

 

T

 

N

 

 

 

 

O

 

 

 

L

 

 

 

I

 

 

 

P

 

 

 

 

F

 

 

 

F

 

PI

O

 

 

 

 

L

 

 

 

O

 

 

 

T

Figure 20 -

Pilot Position

62D4036

21