Monessen Hearth SBV500 Combustion Air Assembly, MODEL OAC-4COMBUSTION AIR ASSEM- BLY, 62D4036

Models: SBV400 BBV400 SBV500

1 40
Download 40 pages 17 b
Page 13
Image 13
COMBUSTION AIR ASSEMBLY

COMBUSTION AIR ASSEMBLY

BBV, SBV Series Natural Vent Gas Fireplaces

MODEL OAC-4 COMBUSTION AIR ASSEM- BLY

1.Remove the cover plate from the 4” outlet opening location on the left outside of the fireplace.

WARNING

DO NOT remove the cover if the outside air will not be connected.

2. Place starting collar (4”) into hole on left side of fire-

 

 

place. Fireplace shortest side of air starting collar

WARNING

Do not use a combustible duct. Always use

NOTE: The air starting collar extends through the

 

through fireplace outer wrap. Fasten starting collar in

 

UL Listed Class 0 or 1 duct material. If nec-

place with four (4) sheet metal screws provided. Fig-

 

essary to splice duct, use Model 403 duct

ure 11

 

connector to splice duct sections.

 

 

fireplace outer wrap. When the air starting collar is

 

 

 

 

securely attached, it will form a seal against the fire-

 

 

place wall.

 

Air Starting Collar

 

 

3.Cut a 6” diameter opening for model OAC-4 in the outside wall covering where the outside vent is to be

located. Figure 13

 

 

Screws

4. Select and cut a piece of duct long enough to attach

 

 

to the fireplace and stick out at least 3” beyond the

 

Duct

face of the wall to which the OAC-4 inlet air vent will

 

 

be attached. Cut duct with a standard pocket knife.

 

 

Figure 12

 

 

 

Left Side of

OAC-4

 

 

Fireplace

 

Screws

 

Starting

 

 

Collar

 

 

 

 

FP2024

Left Side of

 

 

 

Fireplace

 

 

Figure 12 -

 

 

Sheet Metal

Attach Outside duct to Starting Collar

 

 

 

 

Screws

 

 

 

 

6” Diameter

 

 

 

Hole

 

FP2023

Shorter End of Air

 

 

Starting Collar

 

 

 

 

 

Figure 11 -

 

 

Nail

 

 

Hole

Attach Outside Air Starting Collar to Left Side of

 

 

 

Fireplace

Duct Ex-

 

 

tending 3”

 

 

Min.

 

 

5.If using insulating duct, push the insulation back from one end of the duct approximately 2”. Figure 13

6.

Slip the exposed end of the duct over the starting col-

FP2025

AK-4 Inlet Air

 

 

 

 

lar on the fireplace.

 

Vent

Screws

 

 

 

7.

Using the sheet metal screws provided, secure the

Figure 13 -

 

 

 

duct end to the collar attached to the fireplace.

Combustion Air Assembly for Model No. OAC-4

8.Nail or screw the combustion air assembly to the sur- face of the wall.

62D4036

13

Page 13
Image 13
Monessen Hearth SBV500 Combustion Air Assembly, MODEL OAC-4COMBUSTION AIR ASSEM- BLY, connector to splice duct sections