Monessen Hearth SBV400 Fireplace Installation, Use pipe joint sealant that is resistant to

Models: SBV400 BBV400 SBV500

1 40
Download 40 pages 17 b
Page 15
Image 15
FIREPLACE INSTALLATION

FIREPLACE INSTALLATION

BBV, SBV Series Natural Vent Gas Fireplaces

WARNING

Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

CAUTION

A manual shut-off valve must be installed upstream of the appliance. Union tee and plugged 1/8” NPT pressure tapping point should be installed upstream of the ap- pliance. Figure 17

NOTE: The gas line connection may be made using 1/2” rigid tubing or an approved flex con- nector. Since some municipalities have additional local codes, it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54. In Canada CSA-B149 (1 or 2) Installation Code.

A listed manual shut-off valve must be installed upstream of the appliance. Union tee and plugged 1/8” NPT pressure tapping point should be installed upstream of the appliance. Figure 15

IMPORTANT: Install main gas valve (equipment shut-off valve) in an accessible locations. The main gas valve is for turning on or shutting off the gas to the fireplace.

Check your building codes for any special requirements for

 

 

CAUTION

 

locating equipment shut-off valve to fireplaces.

 

Apply pipe joint sealant lightly to male threads. This will pre-

Use pipe joint sealant that is resistant to

 

vent excess sealant form going into pipe. Excess sealant in

 

liquid petroleum (LP) gas.

pipe could result in clogged burner system valves.

 

 

We recommend that you install a sediment trap/drip leg in

 

 

supply line as shown in Figure 15. Locate sediment trap/drip

 

 

leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps mois- ture and contaminants. This keeps them from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

Approved Flexible

Gas LIne

Sediment Trap/Drip Leg

Figure 15 -

Gas Connection

UL/CSA Design-Certified Equipment Shut-off Valve with 1/8” NPT Tap*

 

Natural Gas

 

From Gas Meter

Tee Joint

(5” w.c. to 10.5” w.c. Pressure)

Pipe Nipple

Propane/LP

From External Regulator

 

Cap

(11” w.c. to 13” w.c. Pressure)

 

FP1978