ELECTRICAL INSTALLATION

ELECTRICAL INSTALLATION

BBV, SBV Series Natural Vent Gas Fireplaces

ELECTRICAL WIRING

WARNING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city and state codes. The appliance, when installed, just be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (latest edi- tion) and Canadian Electrical Code, CSA C22.1.

CAUTION

Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous op- eration.

Verify proper operation after servicing.

REMOTE WALL MOUNTED SWITCH

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 16. Do not extend beyond the wall switch wire length provided.

NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local codes.

PILOT

HI

OFF

ON

 

TH

 

TP

 

TH/TP

Figure 16 -

Wall Switch Wiring Diagram

 

 

OPTIONAL REMOTE

 

 

WALL SWITCH

 

SPILL

ON

 

SWITCH

 

ON

RS

OFF

 

OFF

 

 

 

 

OPTIONAL REMOTE

 

 

WALL SWITCH

 

 

ON

 

 

OFF

WARNING

Do not connect wall switch to AC (110 V) circuit.

62D4036

17