BBV, SBV Series Natural Vent Gas Fireplaces | TROUBLESHOOTING | |||
STANDING PILOT IGNITION |
| |||
|
|
|
| |
SYMPTOM | POSSIBLE CAUSE |
| ACTION | |
1. | Spark igniter | A. Wire disonnected. |
| A. Open door and check to make sure wire is connected to |
| will not light pi- |
|
| igniter. |
| lot after repeat- | B. Defective igniter. |
| B. Check for spark at electrode and pilot. If no spark and elec- |
| ed triggering of |
|
| trode wire is properly connected, replace pilot assembly. |
| piezo. | C. No gas or low gas |
| C. Check remote/manual |
|
| pressure. |
| pressure can be caused by bent lines, restricted lines, low |
|
|
|
| pressure line pressure. Consult with plumber or gas supplier. |
|
| D. No Propane/LPG in |
| D. Check Propane/LPG tank. Refill tank. |
|
| tank. |
|
|
|
|
|
|
|
2. | Pilot will not | A. Defective thermocou- |
| A. Check that thermocouple flame impinges on thermocouple. |
| stay lit after | ple. |
| Clean and/or adjust pilot for maximum flame impingement. |
| carefully fol- |
|
| Ensure that the thermocouple connection at the gas valve is |
| lowing lighting |
|
| fully inserted and tight. |
| instructions. |
|
| Disconnect the thermocouple from the valve, place one mil- |
|
|
|
| livolt lead wire on the tip of the thermocouple and the other |
|
|
|
| meter lead wire on the thermocouple copper lead. Start the |
|
|
|
| pilot and hold the valve knob in. If the millivolt reading is less |
|
|
|
| than 15m V, replace pilot assembly. |
|
| B. Defective valve. |
| B. If thermocouple is producing more than 15m V, replace faulty |
|
|
|
| valve. |
|
|
|
|
|
3. | Pilot burning, | A. Defective switch, wall |
| A. Check switch and wire for proper connection. Place jumper |
| valve knob | switch, remote control |
| wires across terminals of switch. If burner comes on, replace |
| tuned to “ON”, | or wire. |
| defective switch. If the switch is OK, repeat the same proce- |
| switch is turned |
|
| dure on remote control. If burner comes on, replace remote |
| to “ON” or “RS”, |
|
| control. Place jumper wire across wire at gas valves (termi- |
| but burner will |
|
| nals marked TH and TP/TH). If burner comes on, wires are |
| not ignite. |
|
| faulty or connections are bad. Replace wire. |
|
| B. Pilot flame too small. |
| B. If pilot flame is not close enough to the thermopile, adjust |
|
|
|
| pilot flame. |
|
| C. Defective or malfunc- |
| C. Check thermopile wire connections to make sure all are tight |
|
| tioning thermopile. |
| and that the thermopile is fully inserted into pilot assembly. |
|
|
|
| Check thermopile with a millivolt meter. Connect leads to TP |
|
|
|
| and TP/TH terminals on the control valve. If meter reading is |
|
|
|
| below 325m V, replace pilot assembly. |
|
| D. Defective valve. |
| D. Turn valve knob to “ON” and switch to “ON”. Take a reading |
|
|
|
| at the thermopile leads (TP & TP/TH) on the valve. If the me- |
|
|
|
| ter reads greater than 175m V and the burner does not light, |
|
|
|
| replace defective valve. |
|
|
|
|
|
4. | Frequent pilot | A. Pilot flame may be too |
| A. Clean and adjust the pilot flame for maximum flame impinge- |
| outage prob- | high or too low, caus- |
| ment on thermocouple. |
| lem. | ing pilot safety to drop |
|
|
|
| out. |
|
|
|
|
|
|
|
5. | The pilot and | A. Inner vent pipe leaking |
| A. Check for flue product leak. Replace defective pipe section. |
| main burner | exhaust gases back |
|
|
| extinguish while | into system. |
|
|
| in operation. | B. Horizontal vent improp- |
| B. Check |
|
| erly pitched. |
| Do not run the pipe level or downward. |
|
| C. Improper vent cap |
| C. Check for proper installation and freedom from debris or |
|
| installation. |
| blockage. |
|
|
|
|
|