BBV, SBV Series Natural Vent Gas Fireplaces | TROUBLESHOOTING | |||
GENERAL TROUBLESHOOTING |
| |||
|
|
|
| |
SYMPTOM | POSSIBLE CAUSE |
| ACTION | |
1. Glass soots. | A. Flame impingement on |
| A. Install log set per instructions. | |
|
| logs. |
| Inspect the injector and air intake area. |
|
|
|
| Make sure this area does not have any blockage from debris |
|
|
|
| and clean. |
|
|
|
| Check gas supply. |
|
|
|
| |
2. Poor draft due | A. Too much offset. |
| A. Reduce offset and/or raise termination. | |
| to venting. |
|
| If thermocouple is producing more than 15m B, replace faulty |
|
|
|
| valve. |
|
| B. Too many elbows. |
| B. Reduce number of elbows. |
|
| C. Vent height too short. |
| C. Raise vent. |
|
| D. Vent too close to roof |
| D. Raise vent. |
|
| line. |
|
|
|
| E. Blockage is rstricting |
| E. Remove blockage. |
|
| venting capacity. |
|
|
|
| F. Incorrect vent type. |
| F. Replace with proper |
|
| G. Venting has been con- |
| G. Replace with proper size. |
|
| structed with too large |
|
|
|
| or too small vent. |
|
|
|
| H. More than one appli- |
| H. Construct a single venting system for each appliance. |
|
| ance is using one vent- |
|
|
|
| ing system. |
|
|
|
|
|
|
|
3. | Poor draft due | A. Cap obstructed by a |
| A. Remove or open enclosure or raise cap above it. |
| to termination | decorative enclosure. |
|
|
| cap. | B. Cap is crushed, |
| B. Replace cap. |
|
| damged or missing. |
|
|
|
|
|
|
|
4. | Poor draft due | A. Buildings, trees, roof |
| A. Maintain proper clearances and heights to external obstruc- |
| to ext. environ- | lines interfering with |
| tions; Be aware of overhangs. |
| ment. | venting. |
|
|
|
| B. Wind |
| B. Use cap designed for high winds; raise venting height. |
|
| C. Vent exposed to cold |
| C. Insulate chase. |
|
| chase. |
|
|
|
| D. Vent exposed to cold |
| D. Enclose vent within home. |
|
| weather. |
|
|
|
|
|
| |
5. Poor draft due | A. Negative air pressure. |
| A. To test for negative air pressure, open a window in the room | |
| to internal envi- |
|
| with the fireplace to see if the unit starts drafting correctly. |
| ronment. |
|
| Make sure the damper system is in the open position. |
6. | Unit shuts down | A. Blockage or restriction |
| A. Check for and remove blockage and light pilot following light- |
| prematurely. | in venting. |
| ing instructions. |
|
|
|
|
|
34 | 62D4036 |