Maintenance
WARNING: Turn off the electrical power supply, the manual gas control valve, and the manual water control valve before servicing.
The unit should be checked once a year or as necessary by a certified and trained technician. If repairs are needed, the repairs should be done by a certified and trained technician.
The following systems and parts should be checked at least once a year:
1.Venting systems
2.Burners
3.Manual operation of the pressure relief valve to ensure correct operation.
4.Periodic cleaning of the water filter, refer to figure below.
5.Heat exchanger. Remove the thermistor and check for a mineral coating . A mineral coating on the thermistor requires flushing the heat exchanger with a descaling solution. Scale build up will void your warranty and shorten the life of your water heater.
18
Troubleshooting
Water Isn’t Hot Enough
The
It Takes Too Long to Get Hot Water
The
The T-K1S Will Not Initiate
First check the flow rate through the unit. If the flow is not 0.75 GPM or greater, the unit will not initiate. Check the filter and the flow sensor for any debris or damage.
Press the lower green button on the GFCI inside the unit. If the red light above it does not come on, then there is a problem with the electrical supply to the unit. If that light does come on, hit the green reset button above the light, and look for the green light on the circuit plate at the top left of the unit. If this light is not lit, there is a problem with the electrical connection between the GFCI and the circuit plate. Contact Takagi Industrial Company for instructions.