Wall Hanging Installation
For a wall mount installation, use
Standing Installation
If the unit is to be installed standing on a surface, adjust the legs so that the unit stands securely and is level (legs can be adjusted up to 1”).
Do not install the unit standing directly on a combustible surface. Use a 3”
Use the included L brackets to connect the unit to a wall to ensure that it does not fall over. These brackets will maintain the required 1” clearance between the back of the unit and a combustible surface.
Outdoor Installation
Follow all local codes, or in the absence of local codes, follow the codes for Installation of Gas Burning Appliances; National Fuel Gas Code ANSI Z221.23 in USA or CAN/CGA B149.1 or .2 in Canada.
For outdoor installation, purchase a
Locate the water heater in an open, unroofed area, and maintain the following minimum clearances from combustible and noncombustible materials.
Outdoor Clearances
Piping side | Minimum of 6” | |
Front (Maintenance space) | Min. 24” | |
Floor (From Non Combustible Base) | Min. 3” off the | |
ground | ||
| ||
Back of heater | 1” | |
Non piping side (in Enclosed Closet) | 2” | |
Non Piping Side (Open Area) | 12” | |
Top of heater (From Overhang) | 36” |
If this unit is installed under an overhang, there must be a 36” clearance from the top of the unit to the overhang, and the surrounding area must be open in front and on the sides of the unit.
WARNING: Do not have the flue terminal pointing toward any opening into a building. Do not locate your heater in a pit or any location where gas and water can accumulate.
WARNING: Do not install the heater where water, debris, or flammable vapors may get into the flue terminal. This may cause damage to the heater.
9