CHECKING GAS PRESSURE

BBV, SBV Series Natural Vent Gas Fireplaces

CHECKING GAS PRESSURE

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.

2.To ease installation, a 30” (762 mm) flex line with manual shut-off valve has been provided with this appliance. Install and attach 1/2” gas line onto shut-off valve.

3.After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a solution of 50/50 water and soap or a gas sniffer.

4.To adjust flame height, turn HI/LO knob to HI to get maximum pressure to burner. Turn HI/LO knob to LO to get minimum pressure.

5.To check gas pressures at valve, turn captured screw counterclockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. Figure 16. After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check test points for gas leaks.

 

Pressure

 

Test “IN”

 

Pressure Test

 

“OUT”

Figure 16 -

HI/LO Knob

Pilot Adjustment Screw

Gas Pressure Check at Gas Valve

 

 

WARNING

Do not use open flame to check for gas

 

 

 

 

leaks.

 

 

 

FP1979

16