Toshiba VF-S9 manual

Models: VF-S9

1 198
Download 198 pages 1.97 Kb
Page 39
Image 39
Manual background

2

 

 

 

 

 

E6580757

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal

Input/output

Function

Electrical

Inverter internal circuits

 

symbol

specifications

 

 

 

 

 

CC

Common to

Control circuit's common terminal

 

 

 

 

 

 

 

Input/output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+24V

 

 

 

10Vdc (permissible

PP

 

 

 

 

PP

Output

Analog input setting power output

load current:

 

 

 

 

 

 

 

 

 

 

 

 

10mAdc)

 

 

 

 

 

 

 

 

Multifunction programmable analog input.

 

 

 

+5V

 

 

 

4-20mA

 

 

 

 

 

 

II

 

Standard default setting: 4(0)~20mAdc in-

 

 

 

 

 

 

Input

(internal imped-

 

 

 

 

 

*

put and 0~50Hz (50Hz setting) or 0~60Hz

 

 

 

 

 

 

 

(60Hz setting) frequency

ance: 400

)

VIA

15K

 

 

1K

 

 

 

 

 

 

 

 

Multifunction programmable analog input.

10Vdc

 

 

15K

 

 

 

VIA

 

 

 

 

 

 

 

Input

Standard default setting: 0~10Vdc input

(internal imped-

I I

150

 

250

 

*

 

 

 

 

and 0~80Hz frequency

ance: 30k

)

 

 

 

 

 

 

 

 

 

 

 

 

 

+5V

 

VIB

 

Multifunction programmable analog input.

10Vdc

 

VIB

15K

 

 

 

 

Standard default setting: 0~10Vdc input

 

 

 

 

Input

(internal imped-

 

 

 

 

and 0~50Hz(50Hz setting) or

 

 

 

 

 

 

 

ance: 30k

)

 

 

 

 

 

 

 

0~60Hz(60Hz setting) frequency.

 

15K

 

 

 

 

 

 

0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JP302

 

0.01μ�

 

 

 

 

 

FMV

 

100K 18K

 

 

 

1mA full-scale DC

 

4.7K

 

 

 

 

 

 

 

 

Multifunction programmable analog out-

ammeter or 7.5Vdc

FM

 

 

 

0.01μ�

 

 

put. Standard default setting: output cur-

1mA full-scale dc

FMC

 

33K

10K

 

 

 

 

FM

Output

rent. Connect a 1mAdc full-scale amme-

voltmeter

 

 

 

 

29K

 

ter or 7.5Vdc (10Vdc)-1mA full-scale volt-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

meter. Can change to 0-20mA (4-20mA)

0-20mA (4-20mA)

 

24V 20K 100K

 

 

by jumper JP302 switching.

full scale DC am-

 

 

 

100

 

 

 

 

meter

 

 

100

 

20K

100K

 

 

 

 

 

 

 

 

CC

Common to

Control circuit's common terminal

 

 

 

 

 

 

 

Input/output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+24V

P24

Output

24Vdc power output

24Vdc-100mA

P24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PTC

 

* The VIA terminal and II terminal cannot be used at the same time.

B-8

Page 39
Image 39
Toshiba VF-S9 manual