INTRODUCTION

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with unvented room heater.

3.Installer should show owner how to start and operate unvented room heater.

Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater.

This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

General Information

This appliance is design certified in accordance with American National Standards Institute Z21.11.2 by the Canadian Standards Association Laboratories as an Unvented Room Heater and shall be installed according to these instructions.

Any alteration of the original design, installed other than as shown in these instructions oruse with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

Well Head Gas Installations

Some natural gas utilities use “well head” gas. This may affect the Btu output of the unit. Contact the gas company for the heating

value. Contact the manufacturer or your gas company before changing spud/orifice size.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

In the State of Massachusetts, unvented propane and natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition).*

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.

High Altitudes

For altitudes/elevations above 2,000 feet (610m) ratings should be reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. Contact the manufacturer or your gas company before changing spud/orifice size.

SPECIFICATIONS

Model

SR-10T

SR-18T

SR-30T

Input BTU/HR (KW/H) Five Plaques

-

-

30,000 (8.8)

BTU/HR (KW/H) Three Plaques

-

18,000 (5.3)

-

BTU/HR (KW/H) One Plaque

10,000 (2.9)

-

-

Height

22” (559mm)

22” (559mm)

22” (559mm)

Width

11 7/8” (302mm)

18” (457mm)

24 1/8” (613mm)

Depth

6 1/2” (165mm)

6 1/2” (165mm)

6 1/2” (165mm)

Gas Inlet

3/8” (10mm)

3/8” (10mm)

3/8” (10mm)

Accessories

 

 

 

Blower

-

SRB-18T

SRB-30T

Floor Stand

SRS-10*

SRS-18

SRS-30

*Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation.

The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFPA54 defines an unconfined space as “a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space.”

16941-5-0907

Page 5

Image 5
Contents Installation Instructions Table of Contents Any safety screen or guard removed for servicing an Important Safety InformationYoung children should be carefully supervised when they LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsUnusually tight construction is defined as construction where Unusually Tight ConstructionGAS Supply Pressure Testing of the Gas Supply SystemGas Supply Recommended Gas Pipe DiameterSR-10T SR-10T ClearancesSR-30T Clearances SR-18T ClearancesOn Sheet Rock Wall Wall Mount InstallationInstallation on Rugs and Tile Optional Floor Stand InstallationLighting Instructions For Your Safety Read Before LightingMain Burner Flame Characteristics Thermostat Operation Pilot Flame CharacteristicsOxygen Depletion Sensor Pilot Figure Main Burner Operation Description of Gas Control KnobRemoving Main Burner Orifices From Main Burner Assembly Appliance MaintenanceRemoving Gas Valve From Casing Assembly Removing Main Burner From Casing AssemblyParts List TroubleshootingHOW to Order Repair Parts SR-18T SR-30T Parts View SR-18T SR-30T Installing Optional Blower SRB-18T or SRB-30T Optional Blower Installation InstructionsOptional Blower Installation Instructions Service Notes

SR-10T-3 specifications

The Empire Comfort Systems SR-10T-3 is a highly efficient, innovative heating solution designed to meet the demands of modern living. This product exemplifies a commitment to quality, reliability, and user-friendly operation, making it an ideal choice for both residential and commercial spaces.

One of the standout features of the SR-10T-3 is its advanced infrared heating technology. This innovation allows the heater to warm objects and people directly rather than just heating the surrounding air, resulting in quick and efficient heat distribution. This means users can enjoy a comfortable environment almost immediately after turning the unit on, reducing wait times that are typically associated with conventional heating methods.

The design of the SR-10T-3 is another highlight. It boasts a compact and sleek profile that can seamlessly integrate into various settings without taking up excessive space. Moreover, this model is available in multiple finishes to complement any décor, ensuring it not only functions effectively but also enhances the aesthetic of the room.

The SR-10T-3 is equipped with an adjustable thermostat, allowing users to customize their heating experience according to their specific needs. This feature promotes energy efficiency, as it helps prevent unnecessary energy consumption by automatically regulating the temperature. In addition, the heater is designed with convenience in mind, incorporating a safety shut-off feature that activates if the unit overheats or tips over, ensuring peace of mind during use.

Durability is another defining characteristic of the Empire Comfort Systems SR-10T-3. Made with high-quality materials, this heater is built to withstand the rigors of daily use while maintaining optimal performance. Its user-friendly controls and straightforward installation process also contribute to its appeal, making it accessible for anyone looking to enhance their heating solutions.

In conclusion, the Empire Comfort Systems SR-10T-3 is an exceptional choice for those seeking an efficient and stylish heating solution. With its infrared heating technology, adjustable thermostat, and durable construction, it stands out in its category, promising reliability and comfort for years to come. Its thoughtful design and commitment to efficiency make it a noteworthy investment for any heating needs.