Empire Comfort Systems SR-10T-3 Appliance Maintenance, Removing Gas Valve From Casing Assembly

Page 15

APPLIANCE MAINTENANCE

Removing Pilot/Thermocouple From Main Burner Assembly Attention:ThethermocoupleCANNOTbereplacedasanindividual item. You must order a new pilot when replacing thermocouple.

1.Turn OFF gas supply to the heater.

2.Turn OFF electrical supply to the heater if optional blower is installed in heater.

3.Remove lower louver from casing assembly (2 screws).

4.Remove reflector from casing assembly (2 screws).

5.Disconnect pilot tubing from pilot (see Figure 14, Page 14). Grasp nut A with a wrench when removing nut B with a second wrench.

6.Remove pilot from pilot bracket (2 screws).

7.Remove thermocouple lead from gas valve.

8.As parts are being replaced in reverse order, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly.

Removing Main Burner Orifice(s) From Main Burner Assembly

1.Turn OFF gas supply to the heater.

2.Turn OFF electrical supply to the heater if optional blower is installed in heater.

3.Remove lower louver from casing assembly (2 screws).

4.Remove reflector from casing assembly (2 screws).

5.Remove pilot bracket from main burner assembly (2 screws).

6.Pivot pilot bracket with attached pilot away from main burner assembly (do not damage pilot tubing).

7.Disconnect supply tubing from orifice holder(s).

8.Remove orifice holder from venturi of main burner assembly (1 screw for each orifice holder).

9.Remove main burner orifice from orifice holder. Attention:The number stamped on the main burner orifice is a millimeter diameter.

10.As parts are being replaced in reverse order, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly.

Removing Gas Valve From Casing Assembly

1.Turn OFF gas supply to the heater.

2.Turn OFF electrical supply to the heater if optional blower is installed in heater.

3.Remove lower louver from casing assembly (2 screws).

4.Remove reflector from casing assembly (2 screws).

5.Remove upper louver from casing assembly (2 screws).

6.If installed, remove optional blower assembly (4 screws).

7.Disconnect inlet supply tubing, outlet supply tubing, pilot supply tubing and thermocouple lead from gas valve.

8.If heater is attached to wall, disconnect gas supply line from inlet regulator.

9.Remove heater from wall.

10. Remove gas valve bracket from casing assembly (4 screws to be removed are located on casing assembly back).

11. Remove hydraulic thermostat bulb from thermostat bulb clip located at casing assembly bottom.

12. Remove gas valve from gas valve bracket.

13. As parts are being replaced in reverse order, check for gas leaks at all gas connections before upper louver, reflector and lower louver are replaced onto casing assembly.

Removing Main Burner From Casing Assembly

1.Turn OFF gas supply to the heater.

2.Turn OFF electrical supply to the heater if optional blower is installed in heater.

3.Remove lower louver from casing assembly (2 screws).

4.Remove reflector from casing assembly (2 screws).

5.Disconnect supply tubing from orifice holder(s).

6.Remove pilot bracket from main burner assembly (2 screws).

7.Remove main burner assembly from casing assembly (4 screws).

8.Remove orifice shield from main burner assembly.Attach orifice shield to new main burner assembly.

9.As parts are being replaced in reverse order, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly.

Piezo Pilot Ignitor Instructions

Depressing the ignitor button completely causes a spark to occur at the pilot.

To light the pilot, it is important that the electrode be 1/8” (3mm) from the pilot. The spark must occur at the point the pilot flame hits the thermocouple.

On a new installation with air in the gas line, it is suggested that a match be used. The match will light the pilot faster than the piezo under this condition.

16941-5-0907

Page 15

Image 15
Contents Installation Instructions Table of Contents Important Safety Information Young children should be carefully supervised when theyAny safety screen or guard removed for servicing an LP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsUnusually tight construction is defined as construction where Unusually Tight ConstructionRecommended Gas Pipe Diameter Pressure Testing of the Gas Supply SystemGAS Supply Gas SupplySR-10T SR-10T ClearancesSR-30T Clearances SR-18T ClearancesOn Sheet Rock Wall Wall Mount InstallationInstallation on Rugs and Tile Optional Floor Stand InstallationLighting Instructions For Your Safety Read Before LightingMain Burner Flame Characteristics Main Burner Operation Description of Gas Control Knob Pilot Flame CharacteristicsThermostat Operation Oxygen Depletion Sensor Pilot FigureRemoving Main Burner From Casing Assembly Appliance MaintenanceRemoving Main Burner Orifices From Main Burner Assembly Removing Gas Valve From Casing AssemblyTroubleshooting HOW to Order Repair PartsParts List SR-18T SR-30T Parts View SR-18T SR-30T Installing Optional Blower SRB-18T or SRB-30T Optional Blower Installation InstructionsOptional Blower Installation Instructions Service Notes

SR-10T-3 specifications

The Empire Comfort Systems SR-10T-3 is a highly efficient, innovative heating solution designed to meet the demands of modern living. This product exemplifies a commitment to quality, reliability, and user-friendly operation, making it an ideal choice for both residential and commercial spaces.

One of the standout features of the SR-10T-3 is its advanced infrared heating technology. This innovation allows the heater to warm objects and people directly rather than just heating the surrounding air, resulting in quick and efficient heat distribution. This means users can enjoy a comfortable environment almost immediately after turning the unit on, reducing wait times that are typically associated with conventional heating methods.

The design of the SR-10T-3 is another highlight. It boasts a compact and sleek profile that can seamlessly integrate into various settings without taking up excessive space. Moreover, this model is available in multiple finishes to complement any décor, ensuring it not only functions effectively but also enhances the aesthetic of the room.

The SR-10T-3 is equipped with an adjustable thermostat, allowing users to customize their heating experience according to their specific needs. This feature promotes energy efficiency, as it helps prevent unnecessary energy consumption by automatically regulating the temperature. In addition, the heater is designed with convenience in mind, incorporating a safety shut-off feature that activates if the unit overheats or tips over, ensuring peace of mind during use.

Durability is another defining characteristic of the Empire Comfort Systems SR-10T-3. Made with high-quality materials, this heater is built to withstand the rigors of daily use while maintaining optimal performance. Its user-friendly controls and straightforward installation process also contribute to its appeal, making it accessible for anyone looking to enhance their heating solutions.

In conclusion, the Empire Comfort Systems SR-10T-3 is an exceptional choice for those seeking an efficient and stylish heating solution. With its infrared heating technology, adjustable thermostat, and durable construction, it stands out in its category, promising reliability and comfort for years to come. Its thoughtful design and commitment to efficiency make it a noteworthy investment for any heating needs.