Hubbell Electric Heater Company Section VI Miscellaneous Charts and Formulas Element Chart

Page 21

SECTION VI – MISCELLANEOUS CHARTS AND FORMULAS

ELEMENT CHART

 

 

Power (Watts)

 

Immersion

Element

Element Part #

120V

208V

240V

277V

480V

Length

Resistance (Ohms)

CH-FO-358

----

3500

----

----

----

11 3/8"

12.36

CH-FO-408

----

4000

----

----

----

11 3/8"

10.82

CH-FO-508

----

5000

----

----

----

13 1/4"

8.65

CH-FO-608

2000

6000

----

----

----

13 3/8"

7.21

CH-FO-304

----

----

3000

4000

----

9 3/4"

19.20

CH-FO-354

----

2500

3500

----

----

9 3/4"

16.46

CH-FO-404

----

3000

4000

----

----

11 1/2"

14.40

CH-FO-454

----

----

4500

----

----

11 1/2"

12.80

CH-FO-504

----

----

5000

----

----

11 1/2"

11.52

CH-FO-604

1500

4500

6000

----

----

13 1/2"

9.60

TGB-1203-480

----

----

----

----

2000

7 5/8"

83.23

TGB-1353-480

----

500

----

1000

3500

12 1/2"

47.56

TGB-2257L

2500

----

----

----

----

9 5/8"

5.76

TGB-1207-240

500

1500

2000

2500

----

13 3/8"

28.80

TGB-1303-480

----

----

 

990

3000

10 1/2"

55.49

TGB-1403-480

----

----

1000

1350

4000

13 5/8"

41.62

TGB-2257-240

----

2000

2500

3500

----

10 5/8"

23.04

TGB-2257-480

----

----

----

----

2500

13 1/4"

66.59

TGB-2457-277

----

----

----

4500

----

13 1/8"

17.05

TGB-2457-480

----

----

----

1500

4500

13 1/4"

36.99

TGB-2503-480

----

1000

----

----

5000

9 3/4"

33.29

TGB-2507-277

----

----

----

5000

----

15"

15.35

TGB-2603-277

----

----

----

6000

----

15 1/2"

12.79

TGB-2603-480

----

----

1500

2000

6000

15 1/2"

27.74

*Red wattage indicates the stamped element rating

Note: Element part numbers, ratings, and lengths are subject to change without notice.

21

Image 21
Contents Electric Heater Company STRATFORD, CT Hubbell Electric Heater CompanyTable of Contents Section Title Page Tank Section I General Description and ConstructionTank Connections Heating ElementControl Thermostat Temperature High Limit SwitchOptions Outer Shell and InsulationPiping Installation Water Heater PlacementElectrical Installation Filling the HeaterFinal Checks Maintenance and Operation Section III Scheduled Maintenance and OperationFreezing Quarterly InspectionAnnual Inspection Symptom Probable Cause Corrective Action / Remedy Section IV TroubleshootingSurface Temperature High Limit CUT-OFF Section V Servicing & Replacement of PartsImmersion Temperature High Limit CUT-OFF Heating Element Page Page Surface Mounted Thermostat Immersion Thermostat Relief Valve Section VI Miscellaneous Charts and Formulas Element Chart Formulas Torque Values